3.1.3 Battery chemical setting:
GEL
:
Sealed lead battery.
AGM
: Lead
battery
batteries, sealed, with electrolyte on
absorbent material.
AGM+
: Lead battery type AGM with the
addition of calcium Ca.
EFB
:
"Enhanced Flooded Battery" lead
battery: lead batteries with evolved
priming capacity suitable for vehicles
with START-STOP functionality.
:
Generic
temperature conditions, under 0°C.
Li
:
Lithium
vehicles.
3.2 LED version battery charger
Charge voltage
Pressing the button in fig. A-1 to set the charge
to 6V (where planned), 12V, 24V(where planned):
the LEDs in fig. A-2 will light up according to the
selected charge voltage.
Press the button in fig. A-1 for 3 seconds
to enable "AGM
"SUPPLY" (fig. A-4) functions:
- AGM
The "AGM" function is useful for charging
"AGM" type batteries: sealed lead batteries,
with electrolyte on absorbent material,
or for charging standard batteries in low
temperature conditions below 0°C "
- RECOVERY
Additional function, to recover sulphated
batteries.
- SUPPLY
Generator SUPPLY mode of voltage 6V (where
planned), 12V or 24V (where planned). Mode
not protected against polarity reversal, short
circuit and wrong choice of voltage.
Attention, the battery charger could
get
damaged
incorrectly.
Warning indications
Yellow LED (
) (fig. A-5) polarity reversal:
Danger!!! Invert the charge clamp
connections!
Orange LED "25%" (fig. A-3): charge in
progress.
Orange LED "50%" (fig. A-3): charge in
progress.
Green LED "75%" (fig. A-3): charge in progress.
Green LED "100%" (fig. A-3): charge completed.
4. INSTALLATION
BATTERY CHARGER POSITION
- Place the battery charger in a stable position
during use.
- Do not lift the battery charger using the
power cable or charge cable.
CONNECTION TO THE MAINS
- The battery charger must only be connected
to a mains power supply with neutral
conductor connected to earth.
Make sure that the mains voltage is equivalent
to the operating voltage.
- The power line must have a protection
system, such as fuses or circuit breakers,
that can support the maximum apparatus
absorption.
- Use the relative power cable when connecting
to the mains.
- Any power cable extensions must be of
suitable size, never lower than that of the
supplied power cable.
type "AGM":
lead
battery
in
battery
for
motorised
", "RECOVERY
if
connected
5. OPERATION
BATTERY CHARGING PREPARATIONS
lead
N.B.: Before charging, make sure the capacity
(Ah) of the batteries to be charged is not lower
than that indicated on the rating plate (C min).
Follow the instructions scrupulously in the order
given below.
- Remove the battery covers (if present), so that
the gas produced during charging can exit.
- Make sure the level of electrolyte covers the
low
battery plates; if they are not covered, add
distilled water until they are submerged by
5-10 mm.
WARNING! BE VERY CAREFUL WHILE
CARRYING OUT THIS OPERATION
BECAUSE THE ELECTROLYTE IS AN
EXTREMELY CORROSIVE ACID.
- Make sure the battery charger is disconnected
from the mains.
- Check the polarity of the battery terminals:
the (+) symbol is positive, the (-) symbol is
negative.
" e
N.B.: If the symbols are not clear, remember
that the positive terminal is not connected to
the vehicle chassis.
- Connect the red charging clamp to the
positive battery terminal (+ symbol).
- Connect the black clamp to the machine
chassis, at a distance from the vehicle battery
".
and the fuel pipe.
N.B.: if the battery is not installed inside the
vehicle, directly connect to the negative
battery terminal (- symbol).
CHARGING
- Power the battery charger by inserting the
power cable into the mains.
- Select the charge voltage using the key in fig.
A-1. The battery charger maintains a constant
charge current/charge voltage during this
phase.
TEST (LCD version)
Power the battery charger by inserting the
power cable into the mains.
Select the TEST function using the key in fig. A-1.
END OF CHARGING
- The LCD version battery charger signals
charging has ended with a positive result
when the symbol
- The LED battery charger, switching on the
green LED "100%" (fig. A-3) signals the end
of charging.
- Disconnect power to the battery charger by
removing the power cable from the mains
socket.
- Disconnect the black charge clamp from the
vehicle chassis or from the negative battery
terminal (- symbol).
- Disconnect the red charging clamp from the
positive battery terminal (+ symbol).
- Return the battery charger to a dry place.
- Close the battery cells again, using the
relative caps (if present).
MAINTENANCE
- Leave the battery charger connected to the
mains.
- Do not interrupt the charge process.
- Leave the charge clamps connected to the
battery even after the charge process has
been completed.
The battery charger will automatically interrupt
and reboot the charge phase maintaining the