used to activate a relay output which can then be used to give a
visual or acoustic alarm or send a signal to a SCADA system via a
communication interface.
If the pump is running and the liquid level in the tank falls below the
dry-running level, the dry-running protection will stop the pump to
ensure that it is not damaged.
Related information
6.1 Setting the application type with Grundfos GO Remote
6.16.1 Automatic operation

4.5 Terminals

1
2
3
IO 242
GENI
33
480Y / 277V
AC
32
31
30
29
28
27
26
25
24
Remember to separate potentially low-voltage cables from
potentially high-voltage cables when connecting them to
the control unit.
Pos.
1
2
3
4
5
6
7
8
9
10
11
12
13
4
5
2
1
6
Max. 2A
Max. 2A
7
8
9
10
11
12
23 22
21 20 19 18 17 16 15 14 13
Description
Current transformer, pump 1.
Optional
Current transformer, pump 2.
Optional
GENIbus
Switch for termination resistor,
SW1
Not for use
Supply voltage, 24 VDC
User-configurable output relay
4, normally closed
User-configurable output relay
4, common
User-configurable output relay
4, normally open
User-configurable output relay
3, normally open
User-configurable output relay
3, common
User-configurable output relay
3, normally closed
Supply voltage for sensors, 24
VDC, max. 50 mA
Pos.
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
See the Appendix for an overview of the panel terminals.

4.6 Identification

4.6.1 Nameplate
1
2
Type:
P.N.
21
U
N
20
P.C.
S.N.
19
I
:
InA:
cc
18
No.
I
pump min
Pumps:
17
OPT:
16
IP Class:
Weight:
kg
15
Assembled in Denmark
P1
EN 61439-2
DK - 8850 - Bjerringbro - Denmark
14
13
12
11
10
Pos.
1
2
3
Description
Ground, GND
User-configurable analog or
digital input
Ground, GND
Digital input 4
Ground, GND
Digital input 3
Ground, GND
Digital input 2
Ground, GND
Digital input 1
Motor-protection feedback
Phase monitoring
Temperature and moisture
sensor input, pump 1
Temperature and moisture
sensor input, pump 1
Temperature and moisture
sensor input, pump 2
Temperature and moisture
sensor input, pump 2
Relay output, pump 1
Common
Relay output, pump 2
Caution, only dedicated current
transformers are to be
connected to these terminals.
3
4
5
°C
T
amb:
kA
I
A
fuse max:
l
pump max
A
A
TY 3432-021-59379130-2014
9
8
7
6
Description
Product name
Serial number
Short-circuit current rating [kA]
13

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis