BTS M30E0-_ _ _-H0001-S04G
Infrared Temperature Sensor
4
Installation and Setup
4.3
1. Roughly align the IR temperature sensor with the target object.
2. Position the sensor so that a maximum is set on the display scale (see Section 13 Sensor Alignment on
page 29).
If the alignment is not correct, radiation from the background will contribute to the measured value calculation and the
display value will be falsified.
Sensor
NOTICE
Damage to the device from direct convective heat
Improper mounting of the sensor can expose it to convective heat, which will damage the unit.
► Install the sensor so that it is not subjected to any direct convective heat.
4.4
Description
Mounting bracket BTS M30
Round sensor holder M30
When using the sensor in harsh surroundings (e.g. flying sparks, weld splatter, UV radiation, etc.), the following
accessories are recommended.
Description
Air shield BTL M30
Cover nut BTS M30
Display protector BTS M30
www.balluff.com