BTS M30E0-_ _ _-H0001-S04G
Infrared Temperature Sensor
11
Configuring the IR Temperature Sensor
11.2.2 Peak Value Detection
The target objects may show locally differing temperatures. Due to the distance-dependent field of view of the sensor,
moving objects would result in fluctuations in the output signal. Peak value detection can be used to hold a local
maximum of the output signal for a settable number of successive measurements.
Example: When there is scaling on steel peak detection makes it possible to display the temperature of the steel while
suppressing scaled and therefore cooler locations.
Setting peak value detection
OUT
[°C]
1
2
1. Turn on peak value detection with [▲] or turn it off with [▼]. Use [↵].
2. Set number of measurements for holding the peak value and confirm
with [↵].
www.balluff.com
Downloaded from
www.Manualslib.com
Output signal without peak value detection
Output signal with peak value detection = 10 (peak value is held for
max. 10 additional measurements)