BTS M30E0-_ _ _-H0001-S04G
Infrared Temperature Sensor
5
Operating Element and Display (Local User Interface)
5.3
► Press and hold [▲▼] (approx. 2 s) to activate or deactivate key lock.
⇒ The lock indicates that key lock is active (graphic) or disappears if inactive.
5.4
After applying power the temperature sensor is ready to use and shows the start screen for 3 s. During this time all
outputs are turned off (high-impedence). The display then changes to the home screen with the current measurement
value as well as the selected settings.
1
2
5.5
By default the display shows the home screen. There the current temperature value and the most important settings
are displayed. Clicking on the [↵] key changes the menu.
1
2
www.balluff.com
Downloaded from
www.Manualslib.com

Button Disable

Note
After activating key lock the display will turn off after 10 s.

Start Screen

Home Screen

manuals search engine
1
1 The lock indicates that key lock is active (graphic).
2 Information how to deactivate the key lock by holding
down (2 s or more) [▲▼]
2
1 Order code
2 Firmware version
1 Effective upper switching thresholds
2 Visualization of the current temperature value in the detec-
tion range as a bar with both effective upper threshold
3
values
3 Current temperature value
1 Special evaluation procedure active
1
2
2 Key lock active
3 Temperature value:
3
LO = Temperature value less than the lower detection
range limit
HI = Temperature value greater than the upper detection
4
range limit
4 IO-Link communication
english