BTS M30E0-_ _ _-H0001-S04G
Infrared Temperature Sensor
15
15.3
15.3.1 Output Data
The sensor sends 2 bytes of process data to the master.
(M-Sequence Type TYPE_2_2)
BDC1...2
Binary status information: (BDC=Binary Data Channel)
1
0
Teach-in
1
0
Out of Range
1
0
Process Data Variable
Relative Temperature
Absolute Temperature
Absolute Temperature
15.3.2 Input data
No input data are transmitted.
32
Downloaded from
www.Manualslib.com
IO-Link Interface
Process data
Octet 0
7
6
5
4
3
Process Data Variable
Temperature value
active
inactive
Teach-in of the switching thresholds active
Teach-in of the switching thresholds not active
Temperature value outside the detection range
Temperature value > upper detection range limit (HI)
or
Temperature value < lower detection range limit (LO)
Temperature value in detection range
Note
The information refers to the temperature value before applying a special evaluation procedure such as avera-
ging.
0...100 % (Unit Style = 0)
250...1250 °C (Unit Style = 1)
482...2282 °F (Unit Style = 2)
english
manuals search engine
2
1
0
7
6
Octet 1
5
4
3
2
1
0