Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Details; Supplementary Documents; Declaration Of Conformity - HEYLO DE2XS Betriebsanleitung

Elektroheizer
Vorschau ausblenden Andere Handbücher für DE2XS:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

specialist company to dispose of and recycle the
device.
See also
 Contacting HEYLO GmbH
23

Technical details

Type:
Temperature range [°C]
Nominal heating output [kW]
Air throughput [m
/h]
3
Sound level at a distance of 3 m
[dB(A)]
Power connection [V/Hz]
IP enclosure class
Current consumption [A]
Fuse protection [A]
Set values for ventilate/heat
50%/heat 100% [W]
Temperature limit for self-
resetting thermostat [°C]
Length [mm]
Width [mm]
Height [mm]
Weight [kg]
NOTICE
The technical details may be changed without prior
notice during the course of development. Some of
the values are approximate.
EN
[
21]
DE2XS
+5 - +40
2.0
90
47
220-240 / 50
20
8.7
10
25/1000/2000
85
178
167
237
2.3
24
Supplementary
documents
24.1

Declaration of conformity

EC Declaration of Conformity IIA
In accordance with the EC Ma-
chinery Directive 2006/42/EC
For device series:
Electric heaters
Type:
DE2XS
HEYLO GmbH, of Im Finigen 9, 28832 Achim, de-
clares that the machines specified comply with the
essential health and safety requirements of the "Ma-
chinery Directive" and the following provisions and
standards, provided they are installed, maintained
and used in accordance with the operating manual
and in accordance with the recognized rules of tech-
nology.
Applicable EC Directives:
Machinery Directive
Low-voltage Directive
EMC Directive
Changes to the machinery made without our con-
sent will render this declaration void.
Applied standards:
DIN VDE 0700, Parts 1 & 30
DIN EN 55014-1:2012-05
EN 60 335-1
EN 60 335-2-30
Achim, Germany,
15/05/2020
Electric heater DE2XS
2006/42/EC
2014/35/EU
2014/30/EU
Dr. Thomas Wittleder
- Chief Executive -
33 / 34

Werbung

Kapitel

Inhaltsverzeichnis
loading