20.1
Decommissioning

Temporary decommissioning

a) Switch off the device at the device switch and
let the cooling time elapse.
b) Disconnect the power plug.
c) Empty the boiler and dispose of the water.
d) Clean the device (see Checking and cleaning
device
[
33]).
 The device has now been temporarily decom-
missioned.

Final decommissioning

✓ Carry out all the steps needed for temporary
decommissioning.
a) Disconnect all connected lines (feed and return,
filling, venting) and electrical cables (power).
 You have now taken the device permanently out
of service.
See also
 Contact to HEYLO GmbH
20.2

Storing the device

a) Switch off the device at the device switch and
let the cooling time elapse.
b) Disconnect the power plug.
c) Empty the boiler and dispose of the water.
d) Clean the device (see Checking and cleaning
device
[
33]).
e) Store the device in a dry place where it is pro-
tected against frost. Observe the prescribed sto-
rage temperature range (see Technical data
[
35]).
20.3

Disposal

The device is primarily made of recyclable materials.
If handled properly, it does not present a hazard to
the operator and the environment. However, opera-
tion of the device might produce waste containing
harmful and/or environmentally hazardous sub-
stances (filters). These materials must be disposed
of properly according to the statutory regulations.
The individual components of the device (e.g.
pumps, metal components, etc.) must be taken to a
qualified disposal and recycling company. Commis-
sion a qualified, specialist company to dispose of
and recycle the device.
See also
 Contact to HEYLO GmbH
EN
[
22]
[
22]
21

Technical data

Model
Prod. no.
Rated heating output [kW]
Pump performance [m³/h]
Electr. power supply [V/Hz]
Power consumption [kW]
Current consumption [A]
Fuse in building installation [A]
Length / width / height [mm]
Weight (empty) [kg]
Noise level at max. speed (3 m)
[dBA]
Protection class [IP]
Max. thermal transfer medium tem-
perature [°C]
Heating operation [°C]
Screed heating program [°C]
22
Supplementary
documents
22.1

Accessories

HEYLO
Description
prod. no.
1200090
Connecting hoses for feed and return
lines (set = 2 hoses) Ø 25 mm, length
3 m
1200091
Filling hose Ø ½", length 5 m
1200092
Power supply cable 230 V/16 A, length
10 m
1200093
Power supply cable 400 V/16 A, length
10 m
1200094
Power supply cable 400 V/32 A, length
10 m
Electric water heater EW 18-e
EW 18-e
1101532
3 / 9 / 18
max. 2.5 /
max. 5.5 m
WC
230/50 or
400/50
3 / 9 / 18
13 (230 V) /
13.2 (400 V) /
26.5 (400 V)
16 / 16 / 32
610 / 590 /
1010
70
25
44
90
5 - 80
25 / 50 / 25
35 / 37

Werbung