11. Technical data

Type of device
Art. No.
Nominal heat output
Voltage/Frequency
Rated current
Protection class
Dimensions H x W x T
Weight
Protection class (IP)
max. surface temperature
Connection cable

12. Fault finding and correction

FAULT
Device does not heat
If the device is supplied with power by mains cable, the work on the electric system may
be carried out by specialist electricians or electrically trained staff in keeping with BGV A
3 only.
Please have the repairing work of infrared heat panel carried out by service partners of HEYLO
Company only.
Decommissioning and disposal of the unit
The unit has been designed for many years of operation.
If it has to be disposed of, the competent legal regulations have to be observed in environmentally-
gentle manner.
W
V/HZ
A
IP
mm
kg
IP
deg. C
CAUSE
8. Fuses of the building's wiring
system are blown.
9. Plug has been pulled out of the
main switch board or of the
extension cable.
10. Supply line faulty.
11. Disconnection from the mains.
12. FI-switch (fast interrupt) of the
building's wiring system has
triggered.
13. Heater is faulty.
14. Overheating (due to coverage)
IRW 200
1110666
200
230 / 50-60
0.9
54
380 x 640 x 40
4.8
54
85
H07BQ-F
3x1.5mm² 3m
REMOVAL
Check until which position
power is available. Remove
defect.
Wait until power comes back
again.
Send the device for repair.
Send the device for repair.
Allow device to cool down, the
IRW will switch back on again
after a waiting period.
11
IRW 500
1110667
500
230 / 50-60
2.2
54
560 x 1200 x 40
9.7
54
85
H07BQ-F
3x1.5mm² 3m
EN

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis