Herunterladen Inhalt Inhalt Diese Seite drucken

General; Technical Data - HEYLO DE 10 E Bedienungsanleitung

Elektroheizgeräte de serie
Vorschau ausblenden Andere Handbücher für DE 10 E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Electric heater
Type DE

1. General

The electric heaters of the DE series are lightweight warm air generators, which are
well transportable. The heating output can be adjusted in three steps; the air flow
cannot be adjusted. The connection of air ducts is not permissible for devices DE 10 E,
DE 20 and DE 30. Electric heaters DE 20 S are suitable for the duct operation with a
maximum duct length of 7.5 m (diameter 305 mm). Only ducts intended for that should
be used.
The electric heater is suitable for point heating (e.g. machine or workspace) or heating
of closed rooms. They are designed for horizontal operation.
Connection to room thermostats is possible,

2. Technical data

Device type
Item No.
Rated heating output
(adjustable)
Warm air flow rate
Temperature increase
(at maximum heating
output)
Voltage/frequency
Power requirement
Current consumption
Fuse protection
(provided by the
customer)
Controller fuse
Connection
Length
Width
Height
Weight
DE 10 E
1101910
kW
9
m³/h
710
K
50
V/Hz
3~400/50
kW
9
A
13
A
16
6.3 time
A
delay
16 A CEE
plug
3 m cable
(5 x 6²)
mm
550
mm
310
mm
475
kg
14
DE 20
DE 20 S
1101911
1101912
6/12/18
6/12/18
1050
1410
70
3~400/50
3~400/50
18
8,7/17,3/26
8,7/17,3/26
32
6.3 time
6.3
delay
32 A CEE
32 A CEE
plug
plug
3 m cable
3 m cable
(5 x 6²)
(5 x 6²)
550
750
310
310
475
475
14
14,5
18
DE 30
1101914
9/18/27
1550
63
70
3~400/50
18
27
13/26/39
32
63
6.3 time delay
63 A CEE plug
3 m cable
(5 x 10²)
550
310
475
16,5
EN

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

De 20De 20 sDe 30

Inhaltsverzeichnis