Infrared oil heater IR 20 H (battery)
d) Clean the device (see Checking and cleaning
the device
[
37]).
The device has now been temporarily decom-
missioned.
Final decommissioning
✓ Carry out all the steps for temporary decommis-
sioning.
a) Disconnect all incoming and outgoing lines
(power supply).
You have now taken the device permanently out
of service.
See also
Contact to HEYLO GmbH
20.2
Storing the device
a) Before putting the device in storage, run it brief-
ly in heating mode with winter diesel to fill the
pipes with a frost-proof fuel.
b) Store the device in a dry place where it is pro-
tected against frost. Observe the prescribed
storage temperature range (see Technical data
and factory settings
[
20.3
Disposal
The device is primarily made of recyclable materials.
If handled properly, it does not present a hazard to
the operator and the environment. However, opera-
tion of the device might produce waste containing
harmful and/or environmentally hazardous sub-
stances (air filters). These materials must be dis-
posed of properly according to the statutory regula-
tions.
The individual components of the device (e.g.
pumps, metal components, etc.) must be taken to a
qualified disposal and recycling company. Commis-
sion a qualified, specialist company to dispose of
and recycle the device.
See also
Contact to HEYLO GmbH
21
Technical data and
factory settings
Model
Prod. no.
Rated heat output [kW / BTU/h /
kcal/h]
Fuel autonomy [h]
Fuel consumption [l/h]
40 / 42
[
24]
40]).
[
24]
IR 20 H
2202601
17 / 58000 /
14600
7
1.35
Model
Admissible fuels
At temperature below 5°C
Fuel tank capacity [l]
Battery voltage [V]
Main power connection [V/Hz]
Power consumption [kW]
Current consumption [A]
Protection class [IP]
Weight without fuel [kg]
Length [mm]
Width [mm]
Height [mm]
Table 9: Technical data
Parameter
Oil pump pressure [bar]
Oil nozzle injection rate [US gal/h] 0.40
Air intake setting
Nozzle type
Table 10: Factory settings
22
Supplementary
documents
22.1
Accessories
HEYLO art.
Description
no.
1240100
Room thermostat
IR 20 H
Diesel, petrol
Winter diesel
11
14
220-240 / 50
0.2
0.4
44
19
560
345
575
Value
9.5
1.5
Danfoss
0.40 gal/h 60°S
EN