Infrared oil heater IR 20 H (battery)
d) Clean the device (see Checking and cleaning
the device
[
37]).
 The device has now been temporarily decom-
missioned.

Final decommissioning

✓ Carry out all the steps for temporary decommis-
sioning.
a) Disconnect all incoming and outgoing lines
(power supply).
 You have now taken the device permanently out
of service.
See also
 Contact to HEYLO GmbH
20.2

Storing the device

a) Before putting the device in storage, run it brief-
ly in heating mode with winter diesel to fill the
pipes with a frost-proof fuel.
b) Store the device in a dry place where it is pro-
tected against frost. Observe the prescribed
storage temperature range (see Technical data
and factory settings
[
20.3

Disposal

The device is primarily made of recyclable materials.
If handled properly, it does not present a hazard to
the operator and the environment. However, opera-
tion of the device might produce waste containing
harmful and/or environmentally hazardous sub-
stances (air filters). These materials must be dis-
posed of properly according to the statutory regula-
tions.
The individual components of the device (e.g.
pumps, metal components, etc.) must be taken to a
qualified disposal and recycling company. Commis-
sion a qualified, specialist company to dispose of
and recycle the device.
See also
 Contact to HEYLO GmbH
21
Technical data and
factory settings
Model
Prod. no.
Rated heat output [kW / BTU/h /
kcal/h]
Fuel autonomy [h]
Fuel consumption [l/h]
40 / 42
[
24]
40]).
[
24]
IR 20 H
2202601
17 / 58000 /
14600
7
1.35
Model
Admissible fuels
At temperature below 5°C
Fuel tank capacity [l]
Battery voltage [V]
Main power connection [V/Hz]
Power consumption [kW]
Current consumption [A]
Protection class [IP]
Weight without fuel [kg]
Length [mm]
Width [mm]
Height [mm]
Table 9: Technical data
Parameter
Oil pump pressure [bar]
Oil nozzle injection rate [US gal/h] 0.40
Air intake setting
Nozzle type
Table 10: Factory settings
22
Supplementary
documents
22.1

Accessories

HEYLO art.
Description
no.
1240100
Room thermostat
IR 20 H
Diesel, petrol
Winter diesel
11
14
220-240 / 50
0.2
0.4
44
19
560
345
575
Value
9.5
1.5
Danfoss
0.40 gal/h 60°S
EN