2. Technical Data for the Model Series K
Type
Item No.
Nominal heat load (kW)
Nominal heat output (kW)
Nominal volumetric air flow at
20° C
Hot air flow at ∆t
(m³/h)
Temperature increase ∆t (K)
Max .available internal static
pressure (Pa)
Sound volume at 5 m distance
dB(A)
Connection for power supply
(V/Hz)
Power input (A)
Power consumption (kW)
Protection class (IP)
Fuel consumption (kg/h)
Heating oil EL
Exhaust gas loss %
Required chimney draught (Pa)
Mass flow of exhaust gas max.
(kg/s)
Equipment dimensions:
Length (mm)
Width (mm)
Height (mm)
Weight with burner (kg)
Exhaust gas pipe –
diameter (mm)
Blow-out nozzle – diameter
(mm)
Thermostat settings:
Ventilator thermostat TR (° C)
Temperature monitor TW (° C)
Safety temperature limiter STB
(° C)
K 25 T
K 50
1101504
1101584
27
54
25
50
1800
3600
2050
4200
45
45
130
200
58
59
230/50
230/50
2,2
2,8
0,50
0,65
44
44
2,3
4,7
8,4
9,0
0
0
0,012
0,025
1450
1640
680
780
820
1070
85
140
150
150
2 x 205
420
35
35
80
80
100
100 (fixed)
(fixed)
23
K 120
K 170
1101625
1101683
120
168
110
153
7900
10130
8900
11000
42
48
250
350
72
52
230/50
400/50
4,9
6,5
1,13
2,65
44
44
10,1
14,0
7,0
8,7
0
0
0,054
0,099
1890
2190
970
1025
1400
1520
225
340
200
200
550
550
35
35
80
80
100 (fixed)
100 (fixed)
K 220
1st / 2nd level
1101684
155 / 234
148 / 219
11400 / 14100
11650 / 16100
43 / 42
360 / 625
59/68,1
400 / 50
7,2 / 10,2
2,50 / 3,58
44
13,1 / 19,0
4,9 / 6,4
0
0,072 / 0,069
2350
1295
1705
480
200
2 x 550
35
80
100 (fixed)
EN