Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications - Fora Diamond PRIMA Bedienungsanleitung

Blutzuckerüberwachungssystem
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18

Specifications

450 measurement results with
Memory
respective date and time
Dimensions
86 x 53.6 x 19.5 mm
Weight
52.4 g (without battery)
Power Source
One 1.5V AAA alkaline battery
External output
USB
Auto electrode insertion detection
Auto sample loading detection
Auto reaction time count-down
Features
Auto switch-off after 3 minutes
without action
Temperature warning
10°C to 40°C (50°F to 104°F), below
Operating Condition
85% R.H. (non-condensing)
Storage/Transportation
-20°C to 60°C (-4°F to 140°F), below
Condition
95% R.H
Measurement Units
mg/dL or mmol/L
Measurement Range
20 to 600 mg/dL (1.1 to 33.3 mmol/L)
Test Sample
Capillary whole blood
Test Result
Plasma equivalent
This device has been tested to meet the electrical and safety requirements
of: IEC/EN 61010-1, IEC/EN 61010-2-101, EN 61326-1, IEC/EN 61326-2-6.
WARRANTY TERMS AND
CONDITIONS
With respect to disposable products, ForaCare Suisse warrants
to the original purchaser that, at time of delivery, each
standard product manufactured by ForaCare Suisse shall
be free of defects in material and workmanship and, when
used for the purposes and indications described on the
labeling, is fit for the purposes and indications described on
the labeling. All warranties for a product shall expire as of the
product expiration date, or if none, after two (2) year from the
original date of purchase, as long as it has not been modified,
altered, or misused. ForaCare Suisse warranty hereunder
shall not apply if: (i) a product is not used in accordance with
its instructions or if it is used for a purpose not indicated on
the labeling; (ii) any repairs, alterations or other work has
been performed by Buyer or others on such item, other than
work performed with ForaCare Suisse's authorisation and
according to its approved procedures; or (iii) the alleged
defect is a result of abuse, misuse, improper maintenance,
accident or the negligence of any party other than ForaCare
Suisse. The warranty set forth herein is conditioned upon
proper storage, installation, use and maintenance in
accordance with applicable written recommendations of
ForaCare Suisse. The warranty furnished hereunder does not
extend to damage to items purchased hereunder resulting
in whole or in part from the use of components, accessories,
parts or supplies not furnished by ForaCare Suisse.
EN-13
PRIMA Owner's Manual

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis