RELAY Menu
R1 Normal Open/Closed Set Open Collector (R1) as Normally Open or
Normally Closed. Default = NORMAL OPEN.
Relay Mode Select the desired mode of operation for the open-collector (R1) output.
Simple Mode: BATCH, VOL PULS, MISSING.
Advanced Mode: OFF, BATCH, HI FLOW, VOL PULS, EOB PULS, MISSING,
OVERRUN, SRC VOL (if SOURCE VOL is set to ON; see OPTIONS menu),
TOT VOL, TWO STG, MULTIPLE, ERROR.
Defaults: Relay 1 = VOL PULS; Relay 2= BATCH; Relay 3 = MISSING.
Note: Same Relay Modes are available for Relays 2 and 3. See pg. 10-12.
Test Relay Select OFF or ON to test relay.
Set Flow In HI FLOW Mode, set fl ow value to activate relay.
Set Hysteresis Prevents the system from chattering around the set point.
In HI FLOW Mode, Relay is energized at Set Flow value and will be de-energized
at Set Flow value minus Hysteresis value.
Set On Delay In HI FLOW, ERROR, MISSING and MULTIPLE Modes, set desired
ON delay. Default = 5 sec.
Note: If MISSING has a delay value, in the Input menu, the relay will be delayed by
the combination of the Input On Delay and the Relay On Delay
Stop Batch? In HI FLOW, MISSING, MULTIPLE, and ERROR Modes,
determines if a Batch is stopped when a Relay Activates. If YES is selected,
Batch will be stopped; if NO is selected, Batch will continue. Default = YES.
Set Overrun Volume In OVERRUN and MULTIPLE Modes, set desired
Overrun Volume.
Note: Overrun Volume must be greater than Manual Overrun Compensation,
otherwise the Overrun Alarm will activate at the end of every batch.
Set Totalizer Volume In TOT VOL Mode, set desired totalizer volume.
Note: This volume is resettable and totalizer volume must be reset to clear relay.
(see Resettable Totalizer, pg. 16)
Set Pulse Volume In VOL PULS Mode, set desired volume.
Set Pulse Width In VOL PULS Mode, set desired pulse width.
View Remote Button Status Press ► to view status of remote buttons.
Remote Button Status Displays status of Remote Buttons: STA (Start),
STP (Stop), RES (Resume). 1 = pressed, 0 = not pressed. Press ENTER to exit.
20
9900-1BC Batch Controller Manual