Installation

The electrical and mechanical in-
stallation must be performed by
qualified personnel.
The electrical appliance is designed
to be built-in to a 2-6 cm thick work-
top in the case of TOP installations;
2.5-6 cm in the case of FLUSH in-
stallations.
The minimum clearance between
the cooktop and wall must be at
least 5 cm at the front, at least 4 cm
on the side and at least 50 cm with
respect to the wall units above.
Note: The suggested clearances
are indicative: when designing the
spaces, follow the instructions of
the kitchen manufacturer.
3.1 Electrical connection
• Disconnect the device from the
electrical network
• The installation must be per-
formed by professionally quali-
fied personnel familiar with the
applicable installation and safety
standards.
• The manufacturer declines any
liability to people, animals or
things in the case of failure to fol-
low the guidelines provided in this
chapter.
• The power cable must be long
enough to allow removal of the
hob from the worktop
• Make sure that the voltage on the
rating plate on the bottom of the
device corresponds to that of the
house where it will be installed.
56
• Do not use extension cords.
• Earthing is required by law
• The earth power cable must be
2cm longer than the other cables
• If the household appliance is not
equipped with a power cable, use
one with a minimum conductor
diameter of 2.5 mm2 for power
up to 7200 Watt; for higher power
levels, the diameter must be 4
mm2.
• At no point along the length of the
cable must it reach a temperature
of 50° C above the room tempera-
ture.
• The device is intended to be per-
manently connected to the elec-
trical network, therefore, make
the connection to the fixed net-
work via a standard omnipolar
switch, which assures the com-
plete disconnection of the mains
under category III overvoltage
conditions, and which is readily
accessible after the installation.
Note: To connect the appliance us-
ing the optional single phase or
three-phase connection, the exist-
ing cable must be removed and re-
placed with another type (not sup-
plied) having the following specifi-
cations: single phase connection:
H05V2V2-F 3G4 cable three-phase
connection: H05V2V2-F 5G2.5 cable