IE
nozzle right to expand the width of
the jet.
In the event of leaks in the
water system, switch off the
equipment immediately at
the on/off switch (3) and dis-
connect the equipment from
the mains at the mains pow-
er cord. Risk of electric shock!
Start afresh with making the
water connections (cf. "Start-
up / Operation" from
point 2.).
If there is still air in the device,
please proceed as follows:
To vent the supply hose:
1. Remove the water connection (6) and
turn the water tap on until the water
comes out without bubbles.
2. Switch off the water tap.
3. Connect the supply hose to the water
connection on the equipment using
the quick connector for garden hose
adapter (7).
4. Fully open the water tap.
To vent the equipment:
5. Switch on the on/off switch (3) until
pressure has built up.
6. Switch off the on/off switch (3).
7. Press the on lever on the gun (9) until
the pressure has gone.
8. Please repeat process 5. to 7. a few
times until there is no more air in the
device.
You can lock the engaging lever
C
(13) of the spray gun (9) by folding
out of the locking lever (14).
Lock the starting lever (13) to
prevent the pressure cleaner from
being inadvertently / accidentally
started.
24
High-pressure /
D
low-pressure operation
The standard Vario nozzle (11) is designed
for either high-pressure or low-pressure
operation.
The standard Vario nozzle (11) is set to
high pressure by default 1 .
Push the tip of the nozzle forward to
change to low-pressure operation 2 .
In this mode (low pressure), the unit will
automatically draw in cleaning agent from
the built-in tank (19) (cf. "Using deter-
gents").
Push in the tip of the nozzle to change to
high-pressure operation.

Interrupting operation

Release the lever of the gun (13).
During prolonged work intervals turn
off the pressure cleaner by its ON /
OFF switch (3).
If the equipment falls over,
switch off the equipment
immediately at the on/off
switch (3) and disconnect the
equipment from the mains at
the mains power cord. Risk
of electric shock! Only now
should the equipment be re-
turned to an upright position.
For your own safety, wait
approx. 5 minutes before re-
connecting to the electricity.