Installation / Operation / Maintenance and Cleaning
Note: Also refer to the assembly instructions for the
accessories.

Operation

Start-up

After the initial commissioning, carefully check all
connections for leaks.
Check the operation of the fitting. To do so, swing
the handle
into all permissible positions.
1
Note: If the tap has not been used for a long peri-
od, flush the pipes thoroughly to avoid stagnation
and build-up of residue.
Open the main water supply.
Lift the handle
1
order to regulate the speed or temperature of
the water.
Hot water:
Swing the handle
1
Cold water:
Swing the handle
1
Note: When the mixer tap is open, pull the diverter
button
upward in order to switch to the shower
7
function
Depress the diverter button
shower function.
Note: Upon closing the mixer tap the shower func-
tion is automatically ended.

Maintenance and Cleaning

Maintaining and cleaning the tap

Please note that sanitary taps require special care and
attention. Therefore, please follow the instructions:
Never clean with petrol, solvents or harsh clean-
ers or hard cleaning brushes, etc. These can
damage the product surface.
Dry your fitting with a cloth after every use to
prevent any lime deposits.
14 GB
274849_Wannenfuell-Brause-Armatur_Modell B_Content_ES.indd 14
and swing it up and down in
to the left.
to the right.
in order to end the
7
Clean the shower valve with a damp, soft cloth
and, if necessary, mild detergent.
Non-observance of the above care advice can be
expected to result in damage to the surfaces of the
product. This will inevitably invalidate the guarantee.

Replacing the cartridge

A cartridge
is a wear part that needs replacing
6
according to the hardness and / or degree of con-
tamination of the water. This becomes evident when
the handle
becomes difficult to move.
1
A new cartridges
can be obtained from the listed
6
service office.
Note: This step requires an open-end spanner
SW 27 mm or fitting pliers.
Proceed as follows to replace the cartridge
Shut off the main water supply. Allow any remain-
ing water in the pipework to drain.
Remove the hot / cold plaque
the handle to the highest position between the
rim and the hot / cold plaque
side of the handle
.
1
Note: Use light pressure to carefully push the
hot / cold plaque
outward so as not to scratch
3
the surface.
Loosen the locking screw
turning it counter-clockwise.
CAUTION! Do not completely unscrew the
locking screw
. Only loosen this as far as is
2
necessary to remove the handle
Remove the handle
1
Unscrew the cartridge covering ring
use pliers or a spanner. Otherwise the product
could be damaged.
Loosen the cartridge locknut
fitting pliers or an open-ended spanner SW 27 mm
and remove the entire cartridge
ting body
.
8
Place the new cartridge
tap
in exactly the same way.
8
Note: Be sure that the seal under the cartridge
is correctly in place. Make sure that the
6
guides are in the corresponding holes.
Reassemble all the above parts. Tighten the
cartridge lock nut
using fitting pliers or an
5
:
6
by adjusting
3
and the out-
3
with an Allen key,
2
.
1
.
, do not
4
below with the
5
from the fit-
6
into the body of the
6
09.12.15 16:15