I
You can use a garden hose to fill the MaxiJacuzzi
If the MaxiJacuzzi
®
to the mains system that supplies drinking water,
this connection must be carried out in compliance
with the EN1717 norm, using "AA", "AB" or "AD" anti-
pollution protection procedures. For further informa-
tion, we recommend you contact your water supply
company and/or your plumber.
I
In the case of indoor installation, it is necessary to remember
that water evaporation from the MaxiJacuzzi
high temperatures are involved) can cause very high levels of
humidity. Natural or forced ventilation helps to maintain personal
comfort and reduce damage to the building due to humidity.
Jacuzzi Europe refuses all responsibility for any damage caused
by excessive humidity or by overflowing water. Consult a spe-
cialist for indoor installation.
I
Remember that it is compulsory to install a multiple-pole section
switch with characteristics that are not less than the ones given in
the chapter "Electrical safety" and
I
The installer must use cables with an adequate cross-section,
protected by a sheath and/or with tubes or ducts, with character-
istics not inferior to type H 05 VV-F.
The entry of cables into the mini-pool up to the electrical box (
2) must be provided at point B or B1, depending on the customer's
installation needs.
Note: The lead sections must take account not only the
systems absorption but also the cable path and the dis-
tances, the chosen protection systems and the specific
regulations for fixed electrical systems in force in the
country where the MaxiJacuzzi
I
The installer must comply with the above regulations, and also use
watertight connectors at connection points. He must also
guarantee compliance with the specific current standards for
systems in the country in which the MaxiJacuzzi
It is mandatory to comply with this instruction. Any other proce-
dure is prohibited.

Electrical safety

The MaxiJacuzzi
®
Premium are
compliance with standards EN60335-2-60: 1997, EN60335-1:
1994+A1+A2+A11+A16, EN60825-1: 1994+A11; EN55014-
1 (19 97), E N55 014-2 (19 97), E N61000-3-2 (19 95),
EN61000-3-3 (1995), EN55022-B (1995), EN50082-1 (1997)
and tested during production to ensure
I
Installation must be carried out
sonnel
, in compliance with current national provisions.
It is the responsibility of the installer to select mate-
rials based on their intended use, to carry out work
properly, to check the condition of the system that
the unit will be connected to and that it ensures
safety of use also concerning maintenance work and
the possibility to examine the system.
®
.
is connected, for periodic filling,
(especially where
®
i
2.
®
is installed.
®
is installed.
safe products, manufactured in
user safety.
by qualified and authorized per-
I
The MaxiJacuzzi
fore they must be permanently connected, without any inter-
mediate connections, to the electrical system and to the pro-
tection system (earth system).
The electrical system of the building must be provid-
ed with a 0.03A differential switch and with an effi-
cient protection (earth) circuit.
Check for proper operation of the differential switch
by pressing the TEST button, which should trip.
I
For electrical connections, the installation of a multiple-pole sec-
tion switch is compulsory (
that complies with safety regulations and, in any case, which can-
not be reached by those using the MaxiJacuzzi
It is mandatory to comply with this instruction. Any other proce-
dure is prohibited.
I
The above-mentioned multiple-pole switches must guarantee a
contact opening of at least 3 mm and must be suitable for the volt-
age and current specified in the chapter "Technical Features".
I
The installation of electrical devices and equipment (sockets,
switches, etc.) near the MaxiJacuzzi
legal standards and regulations in the country where the
MaxiJacuzzi
®
is installed.
i
I
For the equipotential connection as required by specific nation-
al standards, the installer must use the terminal provided (standard
EN 60335.2.60)in the electrical box (
symbol
.
In particular, an equipotential condition must be established for all
metallic masses surrounding the spa, for example water and gas
pipes, metallic platforms, and so on.