Installation
4-1. Attaching the drop-prevention wire
A drop-prevention wire is provided with the unit.
Follow the instructions below to use it to couple the camera to the pan-tilt head.
p When attaching the wire, be absolutely sure to use a Phillips-head screwdriver to tighten the
Notes
2 mounting screws securely.
p Tighten up the mounting screw at the torque levels specified in the table below, and then
check that there is no play.
Mounting screws (Inch thread)
Mounting screws (M4)
For AW-E350/AW-E650
1.
Use the mounting screw for wire (M4C8 mm with flat washer and spring washer) to
attach one end of the wire to the pan-tilt head's arm.
Attach one end of the wire (use the 4.2 mm hole in the mounting fitting) to the
2.
threaded hole on top of the camera using the mounting screw for wire (M4C8 mm
with flat washer and spring washer).
(Be sure to ask your dealer to install the unit.)
Drop-prevention wire (approx. 200 mm long)
4.2 mm
Attaching the wire

Mounting screw for wire

(M4C8 mm) with flat washer and spring
washer [provided with pan-tilt head]
- 30 (E) -
Installation work
1.2 mm
Hole diameter
6.5 mm
4.2 mm
Mounting screw for wire
(M4C8 mm) with flat washer and spring
washer [provided with camera]
Drop-prevention wire
6.5 mm
4.2 mm
Mounting fitting
Clamping torque
2.0 N
m (20 kgf
cm)
1.5 N
m (15 kgf
cm)