VII. SETTING OF THE DEVICE

1. List of setting items

Selecting
Item
device
T0
Needle thread
(Timer)
trimming time
T1
Bobbin thread
(Timer)
trimming time
T2
Heater tempera-
(Timer)
ture setting
DM0
Selection of
sewing machine
operation when
an error occurs
DM1
Selection of
enable/disable
detection of stitch
skipping and
bobbin thread
DM2
Selection of
enable/disable
of bobbin-case
confirmation
DM5
Number of stitch-
es for ignoring
stitch skipping
detection

2. Setting procedure

Inside of
control panel
Device
Selected
number
device
DM
Specified value
Set value
Setting
range
1 to 50 Sets the period of time between the detection of the lower end by
the needle thread trimmer cylinder and the start of rising.
This value is set in increments of 0.1 s. (Set value: 5 → 0.5 s)
1 to 50 Sets the period of time between the detection of the extruding end
by the bobbin thread trimmer cylinder and the start of retraction.
This value is set in increments of 0.1 s. (Set value: 5 → 0.5 s)
0 to 200 Sets preheat time of the heater.
Thread trimming operation is not started until this time has passed.
This value is set in increments of 0.1 s. (Set value: 5 → 0.5 s)
00000
Upon occurrence of a fault, the sewing machine is temporarily
stopped. Temporary stop cannot be cancelled unless the no bob-
bin-thread detection and stitch skipping detection are reset.
00001
Even if a fault occurs, the sewing machine continues operation. It
should be noted, however, the next start of sewing will be disabled
unless the fault is reset.
00000
Enables the stitch skipping detection and bobbin thread detection
00001
Disables the stitch skipping detection
00002
Disables the bobbin thread detection
00003
Disables the stitch skipping detection and bobbin thread detection
00000
Checks presence/absence of the bobbin case at the startup of sew-
ing machine
If the bobbin case is absent, the sewing machine cannot be started.
00001
Does not check presence/absence of the bobbin case at the startup
of sewing machine
0 to
Sets the number of stitches to be sewn before stitch skipping detec-
65535
tion is started
Stitch skipping is ignored from the start of sewing until the set num-
ber of stitches is reached.
Rear face of
control panel
Access window
Contents
1) Press the
ed device.
* When changing the timer, select T/C.
2) Specify the device number with the
3) Keep the
onds.
4) Press the
changed.
5) Increase/decrease the numeric value with the
/
key to set a desired set value.
6) Keep the
seconds to register the set value. Then, the
access window returns to the previous state.
– 16 –
Set value at the
time of shipment
00000
00000
00000
00003
key to select DM as a select-
key held pressed for three sec-
key to blink the digit to be
key held pressed for three
3
3
0
/
key.