Herunterladen Inhalt Inhalt Diese Seite drucken

Accessories - Emerson AVENTICS PE5 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für AVENTICS PE5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
General data
1)
Supply voltage
2)
Current consumption
Electrical safety
Switch outputs
Function
Switching voltage
Max. switching current per switch out-
put
Switching delay
Switching time
Diagnostic output
Analog output signal
Ohmic load for current output
Ohmic load for voltage output
Non-linearity
Accuracy
Non-repeatability
Measuring temperature range
Permissible medium
Compressed air quality acc. to
ISO 8573-1:2010
Pneumatic ports
1)
For power supply, use a limited-energy circuit according to clause 9.4 of stan-
dard UL 61010, 3rd edition.
2)
Due to the capacitive input current, the sensors cannot be connected in series.

13 Accessories

See online catalog
AVENTICS
TM
PE5 | R412010843-BAL-001-AF | English
17 to 30 V DC, protected against polar-
ity reversal
Max. 40 mA (24 V)
Protection class III
PNP/NPN/push-pull, selectable (for the
version with IO link: switch output 1: IO
link/PNP and switch output 2: PNP/
NPN/push-pull, selectable)
Opener/closer, window/hysteresis
function freely adjustable
Supply voltage - 2 V
100 mA
0 to 50 s (programmable)
≤ 5 ms
Switch output 2 configurable
Optional 4 to 20 mA, 0 to 10 V, auto-
matic switching depending on the con-
nected load or settable to a fixed value
Output signals invertible: 20 to 4 mA,
10 to 0 V
< 600 ohms
> 3 kiloohms
≤ ± 0.5% of the range
≤ ± 1.5% of the range
≤ ± 2.0% of the range including temper-
ature error
≤ ± 0.2% of the range
+10 to +60°C
Compressed air
Max. particle size: ≤ 40 µm
3
Oil content: 0 to 40 mg/m
The pressure dew point must be at least
15°C below the ambient and medium
temperatures and must not exceed
3°C.
2x G1/4 acc. to ISO 16030
1x push-in fitting, 4 mm, and 1x G1/4
acc. to ISO 16030
23

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis