Application
Can be used in conjunction with: Pressurised storage
heaters, thermally and hydraulically controlled
instantaneous heaters. Operation with low-pressure
displacement water heaters is not possible.
Specifications
• Flow pressure min. 0.5 bar - recommended 1 - 5 bar
• Operating pressure
• Test pressure
If static pressure is greater than 5 bar, fit pressure
reducer.
Avoid major pressure differences between hot and
cold water supply.
• Flow rate at 3 bar flow pressure:
25 010, 25 011, 25 012
26 003, 26 004, 26 005
• Temperature
Hot water inlet:
Recommended:
• Water connection
Installation
Flush pipes thoroughly.
Install S-unions, dimensions necessary, see fold-out
page I, Fig. [1]
Refer to the dimensional drawing on fold-out page I.
Fit swivel spout (25 010, 25 011, 25 012), see Fig. [1].
Screw-mount the mixer, see Fig. [1] and [2].
1. Turn the pre mounted screw-ring (A) about 30°.
The screw-ring (A) can be placed from flat of nut to
connection piece of wall connection piece (B), see
Figs. [1] and [2].
2. Screw on wall connection piece (B) with open-ended
spanner 32mm until noticeable resistance is felt. To
avoid deformations at wall connection piece (B)
do not tighten too much, see Fig. [2]!
3. Slip screw-ring (A) on again on flat of nut from wall
connection piece (B).
Turn the screw-ring (A) about 30°, so that the screw-
ring (A) is locked.
4. Over the screw-ring (A) the escutcheon (C) must be
screwed against the wall.
Open cold and hot-water supply and check
connections for leakage!
Operation of automatic diverter (D), see Fig. [1].
Turning the handles will release water delivery.
Water will emerge from the bath spout first.
Press diverter knob
Pull diverter knob
Flow is diverted automatically from shower outlet to
max. 10 bar
bath spout when the mixer is turned off.
16 bar
Maintenance
Inspect and clean all parts, replace as necessary and
approx. 25 l/min
grease with special grease (order no. 18 012).
approx. 45 l/min
Shut off cold and hot water supply!
(maximum) 80 °C
(energy saving) 60 °C
I. Replacing the headpart, see Fig. [3].
cold - right
1. Pull off handle (E).
hot - left
2. Unscrew screw (F) and pull off snap insert (G).
3. Unscrew headpart (H) using a 17mm socket wrench.
4. Change either complete headpart (H) or O-ring (J).
Part No. 25 011 / 25 012 / 26 004 and 26 005:
Observe the different replacement part numbers of
the headparts, see fold-out page II.
Observe the correct installation position!
II. Remove non-return valve (08 565), see fold-out
page II.
III. Unscrew and clean mousseur (13 927), see fold-
out page II.
Assemble in reverse order.
Replacement parts, see fold-out page II
( * = special accessories).
Care
For directions on the care of this fitting, refer to the
accompanying Care Instructions.
= to divert flow from bath
spout to shower outlet
= to divert flow from shower
outlet to bath spout