5 On the Advanced Settings window General tab, perform the following
configurations:
Choose Microsoft iSCSI Initiator by the Local adapter drop-down
a
menu.
Choose an iSCSI initiator IP address by the Source IP drop-down
b
menu.
Choose EqualLogic group IP address by the Target Portal drop-down
c
menu.
Select the CHAP logon information check box.
d
Enter the CHAP user name defined in EqualLogic storage,
e
by the User name box.
Enter the CHAP password defined in EqualLogic storage,
f
by the Target secret box.
Click OK.
g
6 On the Log On to Target window, click OK.
7 On the iSCSI Initiator Properties window Targets tab, the status
of the logged on volume should be Connected.
8 Repeat step 3 to step 7 to log on to the same volume for every other iSCSI
initiator IP addresses.
9 Repeat step 3 to step 8 to log on to all other volumes created
for the database.
10 Repeat step 1 to step 9 on all other hosts in the cluster.