0$,17(1$1&(

General recommendations and precautions

The dryer does not need any specific maintenance. Nevertheless,
before carrying out any maintenance or corrective activity, read the
following
recommendations
accordingly:
Check that the on/off switch S1 is in position O.
Disconnect pressure sources and vent the internal pressure of
the system before dismantling any pressurized component.
Use original Atlas Copco spare parts only.
Check the correct operating after maintenance.
! Filters and valves installed between the compressor, the
dryer and the air consumer may need other maintenance
activities than those mentioned below (e.g. draining the fil-
ters and replacing the filter elements). Refer to the appropri-
ate manual for more information.
7528%/(6+227,1*
Symptom
The moisture indicator shows pink
The dryer produces a lot of noise
Insufficient air leaves the dryer
2904 0106 01
and
safety
precautions
and
Possible cause
The dryer has not had the time to regenerate completely.
The drain is not working correctly.
The air flow through the dryer is too high.
The outlet pressure is too low.
The inlet temperature is too high.
Check the silencer and its fixation to the unit.
Too much purge air escapes.

Maintenance activities

Daily
Check the colour of the moisture indicator.
act
Twice a year
Check for damaged wiring or loose connections.
Check for air leaks.
(Every five years)
In normal working conditions, the lifetime of the desiccant is
approximately 5 years. It is recommended to have the desiccant
replaced by an Atlas Copco service technician.
Corrective action
Close the valve installed between the dryer and the application (if
permitted) and have the desiccant regenerated.
Check the drain valve of the filter.
Check for correct application.
Check whether the compressor provides enough air for the
application.
Check the compressor aftercooler.
Replace the silencer if necessary or correct its fixation.
Check the condition of the solenoid valve and replace it if
necessary. Also check the pneumatic valves and the 3-way valve.
I