CD2 – CD3 – CD6
Start up
If the dryer has not been used for more than 3 months, refer to the
chapter "Initial start up". In all other cases proceed as follows:
1.
Cut off the air supply from the compressor towards the dryer by
closing the external inlet valve.
2.
If installed, close the external outlet valve between the dryer unit
and the dry air consumer.
3.
Slowly open the external inlet valve.
4.
Switch the dryer on by plugging the power supply connector or by
switching on the ON/OFF switch (if installed).
5.
Gradually open the air outlet valve.
6.
As required, close the bypass valves of the dryer.
!
Close the external inlet valve in case the compressor needs
to be restarted. The air speed in the start-up phase of the
compressor may damage the desiccant.
During operation
At regular intervals, check the moisture indicator. If is shows clear/
white and the application allows only dry air, shut down the application
and let the dryer regenerate.
The yellow Power On LED should be on continuously (only for 16 bar
units).
Stopping
To stop the dryer proceed as follows:
1.
If installed and if necessary, open the bypass valves of the dryer
so that the application will still receive compressed air.
2.
Close the external inlet valve between the compressor and the
dryer and the external outlet valve between the dryer and the dry
air consumer.
3.
Let the dryer run for a period without consumption, to
depressurize the vessels.
4.
Switch the dryer off by disconnecting the power supply connector
or by switching off the ON/OFF switch (if installed).
!
If the dryer is stopped for a longer period, close the inlet and
outlet valve to avoid moisture from entering the dryer.
6
MAINTENANCE
General recommendations and precautions
The dryer does not need any specific maintenance. Nevertheless,
before carrying out any maintenance or corrective activity, read the
following
recommendations
accordingly:
–
Check that the power supply connector is not connected or that
the unit is switched off.
–
Disconnect pressure sources and vent the internal pressure of
the system before dismantling any pressurized component.
–
Use original Atlas Copco spare parts only.
–
Check the correct operating after maintenance.
!
Filters and valves installed between the compressor, the
dryer and the air consumer may need other maintenance
activities than those mentioned below (e.g. draining the fil-
ters and replacing the filter elements). Refer to the appropri-
ate manual for more information.
Maintenance activities
Daily
–
Check the colour of the moisture indicator.
–
Check that the yellow Power On LED is not flashing (only for 16
bar units).
Twice a year
–
Check for damaged wiring or loose connections.
–
Check for air leaks.
(Every five years)
In normal working conditions, the lifetime of the desiccant is
approximately 5 years. It is recommended to have the desiccant
replaced by an Atlas Copco service technician.