Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications; Applicable For 11 Bar And 16 Bar Units; Applicable For 11 Bar Units Only - Atlas Copco CD100 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 27
CD100 – CD140 – CD230
7(&+1,&$/ 63(&,),&$7,216
A
11
PPLICABLE FOR
BAR AND
Nominal conditions
Compressed air inlet temperature
Outlet pressure dewpoint
Humidity
Limit values
Maximum ambient temperature
Minimum ambient temperature
Maximum compressed air inlet temperature
Minimum compressed air inlet temperature
Specific data
Pressure drop through dryer
In- and outlet connection
Desiccant type
Total amount of desiccant
Recommende filter size
Power consumption
Dimensions (LxWxH)
Mass
A
11
PPLICABLE FOR
BAR UNITS ONLY
Nominal conditions
Compressed air inlet pressure (e)
Limit values
Maximum compressed air inlet pressure (e)
Minimum compressed air inlet pressure (e)
Specific data
Nominal capacity at dryer inlet
Purge air consumption (average during 1/2 cycle)
Time of a half cycle
Purge time
Correction factors
Inlet pressure (bar)
Correction factor Kp
Temperature (°C)
Correction factor Kt
8
16
BAR UNITS
4
0.47
20
1
CD100
35 °C
-40 °C
100 %
40 °C
1 °C
45 °C
1 °C
0.10 bar
1 1/2 "
105 kg
PD/DD 170
10 W
500x910x1620
250 kg
CD100
7 bar
11 bar
4 bar
92 l/s
18 %
180 s
145 s
5
6
7
0.68
0.84
1
25
30
35
1
1
1
CD140
35 °C
-40 °C
100 %
40 °C
1 °C
45 °C
1 °C
0.13 bar
1 1/2 "
Activated aluminium Al
O
2
3
145 kg
PD/DD 170
PD/DD 295
10 W
600x1010x1635
700x1210x1815
310 kg
CD140
7 bar
11 bar
4 bar
135 l/s
18 %
180 s
145 s
8
9
10
1.1
1.2
1.3
40
45
0.84
0.71
2904 0106 01
CD230
35 °C
-40 °C
100 %
40 °C
1 °C
45 °C
1 °C
0.17 bar
2 1/2 "
245 kg
10 W
470 kg
CD230
7 bar
11 bar
4 bar
222 l/s
18 %
180 s
145 s
11
1.38

Werbung