Nominal conditions
Compressed air inlet pressure (e)
Limit values
Maximum compressed air inlet pressure (e)
Minimum compressed air inlet pressure (e)
Specific data
Nominal capacity at dryer inlet
Purge air consumption (average during 1/2 cycle)
Time of a half cycle
Purge time
Correction factors
Inlet pressure (bar)
Correction factor Kp
Temperature (°C)
Correction factor Kt
Usage of the correction factors
When the actual inlet pressure or inlet temperature differs from its nominal value, multiply the nominal capacity with the corresponding correction
factor to obtain the correct capacity.
Dryer dataplate
The dryer dataplate is shown in figure 7:
1.......Dryer type
2.......Dryer serial number
Vessel dataplate
The vessel dataplate is shown in figure 8:
1.......Vessel type
2.......Vessel serial number
2904 0106 01
3.......Maximum pressure
4.......Supply voltage
3.......Manufacturing year
5.......Maximum working pressure 7 ...... Minimum temperature
4.......Total volume of the vessel
6.......Maximum test pressure
11
12.5
13
0.89
1
1.04
20
25
30
1
1
1
5.......Power consumption
6.......Year of construction
8 ...... Maximum temperature
I
NSTRUCTION MANUAL
CD140
12.5 bar
16 bar
11 bar
165 l/s
16 %
250 s
195 s
14
15
16
1.11
1.19
1.24
35
40
45
1
0.84
0.71
7...... EEC mark
9 ...... Corrosion allowance
10 .... EEC mark