INSTALLATION

Sauna heater installation

Preparing for installation is easiest when the heater is lying down.
To install the heater:
1. Lay the heater down front upwards.
2. Slacken the screws and open the cover (see Figure 7, Page
4).
Figure 7: Opening/closing the cover
3.
WARNING! Always check that the heater is con-
!
nected to the correct main/phase voltage.
The heater is connected using standard wiring (Fk or EKK),
approved for fixed installation.
Any single wires (Fk) must be protected in electrical conduits
(VP) to the heater.
Connect the electrical cable (1) to terminal (2) (see Figure
8, Page 4) according to wiring diagram (see The section
called Connection/wiring diagram, Page 7).
Figure 8: Circuit board
1.
Electrical cable
2.
Terminal for connection of electrical cable
3.
Control panel cable
4.
Terminal for connection of control panel
5.
Sensor cable
6.
Terminal for connection of control panel and sensor
7.
Light cable (if relevant)
8.
Terminal for connection of light (if relevant)
4. Connect the control panel cable (3) to terminals (4 and 6) (see
Figure 8, Page 4) according to the wiring diagram (see
The section called Connection/wiring diagram, Page 7).
5. Connect the sensor cable (5) to terminal (6) (see The section
called Connection/wiring diagram, Page 7) according to
the wiring diagram (see The section called Connection/wir-
ing diagram, Page 7).
6. Connect light cable (if relevant) (7) see Figure 8, Page 4
to terminal (8) according to the wiring diagramFigure 15,
Page 7.
7. Close the cover and tighten the screws (see Figure 7, Page
4).
5
3
6
4
7
8