Planning installation

Before starting to install your sauna heater:
Plan where you will position the sauna heater (see The sec-
tion called Positioning the heater - normal installation,
Page 2).
Plan where you will position the control panel (see the control
panel instructions for correct positioning).
Plan where you will position the sensor (see Figure 3, Page
2 samt Figure 5, Page 3).
Position the inlet vent (see The section called Positioning
the inlet vent, Page 3).
Position the outlet vent (see The section called Positioning
the outlet vent, Page 3).
1
Figure 2: Schematic diagram of installation
1.
Sauna heater
2.
Control panel
3.
Sensor
4.
External on/off switch (option)
Positioning the heater - normal installation
DANGER! More than one heater can be installed in
!
the same sauna cabin.
Position the sauna heater:
on the same wall as the door (or the side wall if very close to
the door wall). The heater can also be positioned in a niche
(see Figure 5, Page 3).
at a safe distance from the floor, side walls and interior fittings
(see Figure 3, Page 2).
Position the sensor according to the diagram (see Figure 3, Page
2).
3
4
2
3
2
1
Figure 3: Positioning the heater - normal installation
1.
Minimum distance to side wall: 110 mm
2.
Positioning the sensor: 200 mm from heater
3.
Sensor
4.
Positioning the sensor: 40 mm from ceiling, regardless of
ceiling height
5.
Minimum distance to ceiling: 1200 mm
6.
Minimum distance to interior fittings: 100 mm
7.
Minimum ceiling height: 1900 mm
8.
Minimum distance: 20 mm
9.
Minimum distance to interior fittings: 30 mm
10.
Distance to floor: 100 mm
If the wall on which the sensor is to be installed is made of highly
heat insulating material (e.g. concrete, brick etc.) or if the wall
is made of toughened glass, the sensor can be installed directly
above the heater (above the centreline of the heater seen from
the front and side see Figure 4, Page 2).
1
Figure 4: Sensor installation on ceiling on centreline of heater
seen from the front and side
1.
200 mm
Positioning the heater - niche installation
To position the sauna heater in a niche:
1. Position the heater at a safe distance from the floor, side walls
and interior fittings (see Figure 5, Page 3).
4
5
6
7
9
8
10