BEFORE INSTALLATION
Parts
Check that the following parts are included in the packaging:
2
3
1
8
7
Figure 1: Sauna heater parts
1.
Sauna heater
2.
Herb bowl/air humidifier
3.
Brackets x 4
4.
Sensor/temperature cut-out C-P, cable length 4 m
5.
Control panel
6.
Warning sticker in ten languages
7.
3 mm Allen key
8.
Lock screws x 2
9.
Bracket screws x 8
10.
Connectors x 3
11.
Screws RXS/A2 PHIL B6X25 x 2
12.
Clips TC (5-7) x 10
Contact your dealer if anything is missing.
The following control panels are compatible with Sense Plus:
CC10, CC50, CC300, EC50 and h1.
Control panel CC10 is supplied with Sense MPE.
Cable between heater and control panel must be: shielded cable
(LiYCY 8X0. 25 mm²).
Installation requirements
For detailed instructions concerning sauna construction/ventila-
tion etc., go to: http://www.tylö.se/byggabastu and download this
document: "Building a sauna.pdf".
To ensure safe use of the heater, check that the following criteria
are met:
•
The sauna cabin shall meet the requirements for ceiling
height and dimensions according to: "Building a sauna.pdf".
4
5
6
10
11
9
•
The sauna cabin shall meet the requirements for insulation
and materials according to: "Building a sauna.pdf".
•
Cable (EKK) or electrical ducting for connecting the heater
must be run on the outside of the heat insulation.
•
Cable installation must be correctly performed (see The sec-
tion called Connection/wiring diagram, Page 7).
•
Fuse size (A) and power cable size (mm²) must be suitable for
the heater (see The section called Connection/wiring dia-
gram, Page 7).
•
Sauna ventilation must comply with the instructions in this
manual (see The section called Positioning the inlet vent,
Page 3, The section called Positioning the outlet vent,
Page 3).
•
The position of the sauna heater, control panel and sensors
must comply with the instructions in this manual.
•
Heater output (kW) must be suitable for the sauna volume
(m³) (see Table 1, Page 1). Minimum and maximum
volumes must not be exceeded.
NOTE! A brick wall without heat insulation in-
creases the warm-up time. Each square metre of
plastered ceiling or wall surface is equal to an addi-
tional 1.2–2 m³ of sauna volume.
Table 1: Output and sauna volume
Output kW
6.6
8
DANGER! Incorrect ventilation or heater positioning
!
can lead to the wooden panels drying out, causing a
risk of fire under certain circumstances!
DANGER! Insufficient insulation of the sauna cabin
!
can mean a risk of fire!
DANGER! Use of the wrong materials in the cab-
!
in, such as chipboard, plasterboard etc. can mean a
risk of fire!
DANGER! Connection of the heater must be per-
!
formed by a qualified electrician according to the
applicable regulations!
Installation tools
The following tools and materials will be required for installation
and connection:
•
spirit level,
•
adjustable spanner,
•
electric drill,
•
screwdriver.
Sauna volume min./max. m³
4-8
6-12
1