4.9 Colour change display (coLr)
The colour of the characters in the display can be set via the parameter [coLr]
(→ 10.4.4). With the set parameters rED (red) and GrEn (green), the display is
permanently set to one colour� If the parameters rxou and Gxou are set, the colour
of the characters changes depending on the process value:
Parameter
settings
SP1/
SP2
MAW
FL1/
FL2
MAW
MAW = initial value of the measuring range, MEW = final value of the measuring range

4.10 IO-Link

This unit has an IO-Link communication interface which enables direct access to
process and diagnostic data� In addition it is possible to set the parameters of the
unit during operation� Operation of the unit via IO-Link interface requires an IO-
Link capable module (IO-Link master)�
With a PC, suitable IO-Link software and an IO-Link adapter cable communication
is possible when the system is not in operation�
OUT1
OUT2
Colour change to ...
r1ou
r2ou
red
G1ou
G2ou
green
Hysteresis function:
Colour change if process value
MEW
is above the set point
FH1/
FH2
Window function:
Colour change if process value
MEW
is within the window range
UK
53