3.6. Electric heater insulation resistance

When performing the final inspection of the electrical
installations, a "leakage" may be detected when
measuring the heater's insulation resistance. The
reason for this is that the insulating material of the
heating resistors has absorbed moisture from the
air (storage transport). After operating the heater
for a few times, the moisture will be removed from
the resistors.
Do not connect the power feed for the heater
through the RCD (residual current device)!

4. SPARE PARtS

1.
Heating element 1500W/230V
2.
Heating element 2000W/230V
3.
Heating element 2670W/230V
4.
Air flow spoiler
5.
Thermostat/overheating limiter
6.
Control panel
7.
Power unit
8.
ON/OFF Electric switch
9.
Wall installation flange
10.
Control cable
DE

3.6. Isolationswiderstand des Elektrosaunaofens

Bei der Endkontrolle der Elektroinstallationen kann
bei der Messung des Isolationswiderstandes ein
"Leck" auftreten, was darauf zurückzuführen ist, daß
Feuchtigkeit aus der Luft in das Isolationsmaterial der
Heizwiderstände eingetreten ist (bei Lagerung und
Transport). Die Feuchtigkeit entweicht aus den Wi-
derständen nach zwei Erwärmungen.
Schalten Sie den Netzstrom des Elektrosaunaofens
nicht über den Fehlerstromschalter ein!

4. ERSAtZtEILE

Heizelement 1500W/230V
Heizelement 2000W/230V
Heizelement 2670W/230V
Luftleit führung
Thermostat/Überhitzungsschutz
Bedienfeld
Leistungseinheit
EIN/AUS-Schalter
Montagemanschette
Steuerkabel
ZSK-690
ZSK-700
ZSK-710
ZSM-40
WX-232
ZSM-90T
ZSM-80T
ZSK-684
ZSME-80
17