Electrical Safety - Jacuzzi J-400 Serie Vorinstallationsblatt

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
If the spa is connected, for periodic filling, to the
mains system that supplies drinking water, this con-
nection must be carried out in compliance with the
EN1717 norm, using "AA", "AB" or "AD" anti-pollu-
tion protection procedures. For further information,
we recommend you contact your water supply com-
pany and/or your plumber.
I
For indoor installation, it is necessary to remember that water
evaporation from the spa (especially where high temperatures are
involved) can cause very high levels of humidity. Natural or forced
ventilation helps to maintain personal comfort and reduce damage
to the building due to humidity.
Jacuzzi Europe refuses all responsibility for any damage caused
by excessive humidity or by overflowing water. Consult a spe-
cialist for indoor installation.
I
The installer must use suitable isolating cables, protected with a
sheath and/or tubes or pipes with characteristics which are not
inferior to type H 05 VV-F, keeping in mind that the heater power
supply is separete from that of the hydromassage pumps.
The entry of cables into the mini-pool up to the electrical box (
2) must be provided at point B or B1, depending on the customer's
installation needs.
Note: The lead sections must take account not only the
systems absorption but also the cable path and the dis-
tances, the chosen protection systems and the specific
regulations for fixed electrical systems in force in the
country where the spa is installed.
I
The installer must comply with the above regulations, and also use
watertight connectors at connection points. He must also
guarantee compliance with the specific current standards for
systems in the country in which the spa is installed.
It is mandatory to comply with this instruction. Any other proce-
dure is prohibited.

Electrical safety

The Premium spas are safe products, manufactured in compli-
ance with standards
60335-1: 2002, 60335-2-60: 2003,
60825-1: 1994+A1+A2, EN 55014-2, CISPR 22 CLASS B,
EN 61000-3-2, EN 6100-3-3 and tested during production to
ensure
user safety.
I
Installation must be carried out
sonnel
, in compliance with current national provisions.
It is the responsibility of the installer to select mate-
rials based on their intended use, to carry out work
properly, to check the condition of the system that
the unit will be connected to and that it ensures safe-
ty of use also concerning maintenance work and the
possibility to examine the system.
by qualified and authorized per-
I
The Premium spas
permanently connected, without any intermediate connec-
tions, to the electrical system and to the protection system (earth
system).
The electrical system of the building must be pro-
vided with a 0.03A differential switch and with an
efficient protection (earth) circuit.
Check for proper operation of the differential switch
by pressing the TEST button, which should trip.
Parts incorporating electrical components, except
remote control devices, must be located or fixed so
that they cannot fall into the spa.
Live components and equipment must be out of
reach of individuals in the spa.
i
I
(
2) For connection to the electric mains, you will need to
install two isolating multi-pole switches, which will ensure complete
disconnection in the instance of a category III over voltage; these
devices must be connected to an area that complies with the safe-
ty regulations governing bathroom safety and in any case out of
the reach of the people using the spa.
It is mandatory to comply with this instruction. Any other proce-
i
dure is prohibited.
I
The disconnection devices must be installed in the power sup-
ply network according to the installation instructions.
I
The installation of electrical devices and equipment (sockets,
switches, etc.) near the spa must be in compliance with legal stan-
dards and regulations in the country where the spa is installed.
I
For the equipotential connection as required by specific nation-
al standards, the installer must use the terminal provided (standard
EN 60335.2.60)in the electrical box (
symbol
.
In particular, an equipotential condition must be established for all
metallic masses surrounding the spa, for example water and gas
pipes, metallic platforms, and so on.
15