Connect the solenoid for filling/topping off the compensa-
tion tanks (3/4" connections) to the water mains.

ELECTRIC CONNECTIONS AND SAFETY

I
GENERAL NOTICES
The installer is responsible for choosing wires with charac-
teristics and nominal section that are suitable for the specific
current input of the spa (see pre-installation instructions).
The cable path, choice of materials and most suitable in-
stallation solutions are left to the professional knowledge and
experience of the installer; it is his responsibility to guarantee
and certify the installation.
Make the connection on the terminal board as shown in
NOTE: if power is provided with a double single-phase
line(220-240 V 2+N~) or with a tri-phase line with a neu-
tral wire (380-415 V 3+N~), before making the connec-
tion you must cut the indicated jumpers, located near
the power supply terminal block.
To ensure the degree of protection against water as required
by standards, a cable clamp has been installed to make con-
nection the electrical system easier.
The installer must in any case connect the phase wire(s) to
the correct terminal and the neutral wire to terminal N (in the or-
der indicated). He must also connect the earth wire to the ter-
minal identified by the symbol
components in the electrical box. When installation is complete,
the cable clamp must be closed and the cover of the electrical
box must also be hermetically closed.
IMPORTANT: for Countries where 220-240V voltage
is supplied by a two-phase system (L+L), the connec-
tion has to be made on terminals L1 and N anyway.
In the instance where a cable radio system is present, con-
nect it to the electrical box, as indicated
I
LIMITATION OF ELECTRICAL CONSUMPTION
If there is not enough electrical energy and you decide to ac-
tivate the consumption limiter, the system software must be
configured for proper operation of the spa:
Press and hold the "Light"
til the message"cFn" appears.
If necessary, use the "Up"
scroll the menu until you see "cFn". Press the "Light"
gain to confirm the option.
Now insert the password 123 as follows:
- use the "Up"
and/or "Down"
number.
i
, taking care not to damage the
i
3.
key for about 12 seconds, un-
and/or "Down"
keys to
key a-
keys to insert the first
- confirm the selection by pressing the "Light"
Perform the same steps to insert the other two numbers.
Once you have inserted the password, the display will show
the message I1x (parameter for temperature unit of measure.
Press the "Light"
"x" may be 1 or 0; the factory setting is 1).
NOTE: in some models, "x" may assume values within the
range of 16 to 32 (amps) and may be modified according to
2 amp intervals therefore allowing for the control of the ope-
rating power; the factory setting is 32.
Use the "Up"
2.
then confirm the selection with the "Light" * key. The display will
show the message I3 0. Press the "Light"
it the procedure and memorize the new values. Make sure you
do not modify parameter I3 0. The display will go off for a mo-
ment, and then it will come on again.
- If no key is pressed for 20 seconds, you will exit the proce-
dure and any changes made will not be saved.
NOTES
- When I2 is 0 (or to 16, in some models), electrical consump-
tion of the spa is limited to 16A. In these conditions you can si-
multaneously activate a hydromassage pump and the blower.
When you activate the other pump, the one in operation is shut
off but the blower stays on.
If the heater is active, turning on any load (pumps and/or blow-
er) will de-activate the heater.
When parameter I2 is 1 (or to 32, in some models), max-
imum electrical consumption is selected. In these conditions
it is possible to activate both the hydromassage pumps and the
blower.
If the heater is active, it is possible to have only two loads ac-
tive (pumps, or a pump and a blower). Turning on a third load
will shut off the heater.
- It is not advisable to activate the consumption limiter if the s-
pa is installed where temperatures often drop below 0 °C because
this limits the anti-freeze protection (see related chapter).
- The setting of parameter l2 (setting which can be made at
intervals of 2) allows for optimised management of electrical
consumption
25
key again to go to parameter I2x (where
and/or "Down"
keys to change "x" and
key.
key again to ex-

Werbung