8
Disassembly
610.44495.40.330 · 09.2013
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
8.2
Dismantle the ventilator
If the G-BH2 is provided with an auxiliary ventilator (B), then continue disas-
sembly as per Disassembling the auxiliary ventilator [➙ 59].
▪ Remove the fan guard screws (503).
▪ Remove the fan guard (500).
▪ Remove the circlip of the auxiliary ventilator (506) if available using circlip pli-
ers.
▪ Pull the external fan (501) off, use two slotted screwdrivers to prise it off if
necessary.
▪ Remove the feather key (505) if available using pliers.
28
/
67
Tel. 071 918 60 60, Mail: v-g@prematic.ch
© Gardner Denver Deutschland GmbH