Disassembly options
610.44495.40.330 · 09.2013
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
10.5
Disassembly of flange without silencer
▪ Remove the screws (142).
▪ Remove the flange (034).
▪ Remove the protective grid (150) from the flange (034).
▪ Loosen the screws (051/053).
▪ Remove the manifold (048) and stepped pipe (049).
If the G-BH2 is equipped with standard silencers, then continue disassem-
bly with Disassembly of the silencer [➙ 27].
If the G-BH2 is equipped with standard ventilator, then continue disassem-
bly with Dismantle the ventilator [➙ 28].
If the G-BH2 is provided with an auxiliary ventilator (B), then continue disas-
sembly as per Disassembling the auxiliary ventilator [➙ 59].