© Gardner Denver Deutschland GmbH
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
11.4
Assembly of integrated frequency inverter 2FC4..2-
1ST/PB/CB/SC
▪ If available, insert the gasket (641) into the intermediate plate (649).
▪ If available, place the intermediate plate (649) on the terminal box opening of
the motor housing (001) with an overhang on the ventilation side.
▪ If available, insert the screws (642) into the holes of the intermediate plate
(649) and screw them to the terminal box in the motor housing (001).
M4: M
= 2.3 – 2.7 Nm ( 1.70– 2.00 ft lbs) / M5: M
A
3.70 ft lbs)
▪ Insert the gasket (643) into the adapter plate (648).
▪ Place the adapter plate (648) on the intermediate plate (649) or the terminal
box opening of the motor housing (001) with an overhang on the ventilation
side.
▪ Insert the screws (638) into the holes of the adapter plate (648) and screw
them to the intermediate plate (649) or the terminal box in the motor housing
(001).
M
= 2.3 – 2.7 Nm ( 1.70– 2.00 ft lbs)
A
▪ Wire all electrical connections to the adapter plate (648) according to the
marks or the circuit diagram.
▪ Plug the frequency inverter (600) into the adapter plate (648) from above with
overhang on the ventilation side.
▪ Screw the frequency inverter (600) and the adapter plate (648) in using screws
(637).
M
= 4.2 – 5.0 Nm (3.10 – 3.70 ft lbs)
A
Complete the assembly using Testing [➙ 66].
Assembly options
63
/
67
Tel. 071 918 60 60, Mail: v-g@prematic.ch
11
= 4.2 – 5.0 Nm (3.10 –
A
09.2013 · 610.44495.40.330