The cooling module's
design
XL1
QN15
QN13
QN14
QN16
XL16
XL17
XL7
QN13
Reversing valve 1, active cooling
QN14
Reversing valve 2, passive cooling
QN15
Reversing valve 3, active cooling
QN16
Reversing valve 4, passive cooling
XL1
Heating medium supply
XL2
Heating medium return
XL6
Brine in
XL7
Brine out
XL8
Docking in (HM from heat pump)
XL9
Docking out (HM to heat pump)
XL16
Docking in (Brine from heat pump)
XL17
Docking out (Brine to heat pump)
Designations according to standard EN 81346-2.
24
XL2
XL6
XL9
XL8
ELECTRICAL CONNECTION
AA5-F1
AA5-X10
AA5-X9
AA5-X2
AA5
W101
SF1
Switch
AA5
Accessory card
AA5-X2
Terminal block, sensors and external blocking
AA5-X4
Terminal block, communication
AA5-X9
Terminal block, circulation pump and reversing
valves
AA5-X10
Terminal block, reversing valves
AA5-S2
DIP switch
AA5-F1
Fine wire fuse (T4A, 250V)
W101
Cable with connection plug, supply
W102
Cable, communication with heat pump or previ-
ous accessory card
SF1
AA5-X4
AA5-S2
W102
HPAC S40 | GB