Nibe HPAC S40 Installateurhandbuch

Nibe HPAC S40 Installateurhandbuch

Klimamodul
Vorschau ausblenden Andere Handbücher für HPAC S40:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

IHB 2110-2
531577
HPAC S40
SE
Installatörshandbok
Klimatväxlingsmodul
GB
Installer manual
Climate exchange module
DE
Installateurhandbuch
Klimamodul

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Nibe HPAC S40

  • Seite 1 IHB 2110-2 531577 HPAC S40 Installatörshandbok Klimatväxlingsmodul Installer manual Climate exchange module Installateurhandbuch Klimamodul...
  • Seite 3: Inhaltsverzeichnis

    Viktig information Allmänt Röranslutning Systemprincip Elinkoppling Programinställningar Tekniska uppgifter English Important information General Pipe connections System diagram Electrical connection Program settings Technical data Deutsch Wichtige Informationen Allgemeines Rohranschluss Systemprinzip Elektrischer Anschluss Programmeinstellungen Technische Daten Wiring diagram Kontaktinformation HPAC S40 | DE...
  • Seite 4: Viktig Information

    Max system- Definieras tryck, värmebära- av huvudpro- Läs installatörshandboken. dukt Max flöde Definieras av huvudpro- dukt Max tillåten om- °C givningstempera- HPAC S40 ska installeras via allpolig brytare. Kabelarea ska vara dimensionerad efter vilken avsäkring som används. HPAC S40 | SE...
  • Seite 5 Den ska lämnas in till särskilda avfallsstationer eller till återförsäljare som tillhandahåller denna typ av service. Felaktig avfallshantering av produkten från användarens sida gör att administrativa påföljder tillämpas i enlighet med gällande lagstiftning. HPAC S40 | SE...
  • Seite 6: Allmänt

    Värmepumpen har ett inbyggt styrsystem för styrning av värme/kyla, inbyggda cirkulationspumpar och ansluts via HPAC S40-modulen till yttre kollektor och husets klimatsystem för värme och kyla. QN15 Värmeväxlingen från värmekällan (berg, mark eller sjö) sker via ett slutet köldbärarsystem där vatten blandat...
  • Seite 7: Transport Och Förvaring

    MONTERING HPAC S40 monteras på väggen. Skruva först upp den medlevererade upphängningskon- solen på väggen. Häng sedan upp HPAC S40 på konso- len. HPAC S40 är nu till viss del skjutbar i sidled, vilket underlättar vid rörinstallation. AA5-F1 AA5-X10 AA5-X4...
  • Seite 8: Röranslutning

    Denna systemlösning innebär att köldbäraren varmvattenberedning. kommer att cirkulera även genom värmesyste- met. Rörinkoppling sker i botten och på toppen av HPAC S40. Montera erforderlig säkerhetsutrustning, avstängnings- Kontrollera att alla ingående komponenter är ventiler (monteras så nära kylmodulen som möjligt), konstruerade för aktuell köldbärare.
  • Seite 9 På sidan av ventilerna finns skyltar där kontroll kan ske att ventilernas utgångar pekar enligt ovanstående. TÄNK PÅ! Vid ändring av värme-/kylläge föreligger en fördröjning på ca 60 sek innan ändringen av ventilernas läge äger rum. HPAC S40 | SE...
  • Seite 10 För att undvika kondensbildning måste rörledningar och övriga kalla ytor isoleras med diffusionstätt material. Då systemet kan köras med låga temperaturer måste en eventuell fläktkonvektor vara utrustad med droppskål och avloppsanslutning. TRYCKFALLSDIAGRAM HPAC S40 (25% prorylenglykol, 5 °C) Tryckfall Tryckfall (kPa) (kPa) Flöde (l/s) Flöde...
  • Seite 11: Systemprincip

    PRINCIPSCHEMA VÄRMEPUMP MED Systemprincip HPAC S40 OCH 4-RÖRS UKV I de fall då systemvolymen i klimatsystemet är under -CP10 20 l/kW (värmepumpseffekt vid 7/45 °C) och/eller flödet -EQ1-GP10 i klimatsystemet stryps okontrollerat installeras en UKV- -EB100-BT25 tank som volym- och flödesförhöjare.
  • Seite 12: Elinkoppling

    ANSLUTNING AV KOMMUNIKATION Elinkoppling HPAC S40 innehåller ett tillbehörskort (AA5) som ansluts direkt till huvudproduktens grundkort (plint AA2-X30). OBS! Om fler tillbehör ska anslutas, eller redan finns installe- All elektrisk inkoppling ska ske av behörig rade, ansluts korten i serie.
  • Seite 13 24 23 22 21 20 19 18 17 16 15 14 13 CIRKULATIONSPUMP (EQ1-GP10) En extern cirkulationspump (GP10) för klimatsystemet AA5-X2 kan vid behov anslutas till HPAC S40. Passiv kyla Anslut cirkulationspumpen (GP10) till AA5-X9:8 (230 V), AA5-X9:7 (N) och X21:5 (PE).
  • Seite 14: Programinställningar

    DIP-SWITCH Programinställningar DIP-switchen (S2) på tillbehörskortet (AA5) ska ställas in enligt nedan. Programinställningen av HPAC S40 kan göras via start- guiden eller direkt i menysystemet i din kompatibla vär- mepump. TÄNK PÅ! Se även installatörshandboken för din kompa- tibla värmepump.
  • Seite 15 Vid överkapacitetsläge på "SG Ready" och kyldrift mins- Hastighet i aktiv kyla kas parallellförskjutningen för inomhustemperaturen med "-1". Om rumsgivare finns installerad och aktiverad Inställningsområde: 1 - 100 % minskas istället önskad rumstemperatur med 1 °C. HPAC S40 | SE...
  • Seite 16 Hast. i vänteläge, kyla: Här ställer du in vilken hastighet me. Om BT74 är installerad kommer den att vara förvald köldbärarpumpen ska ha i vänteläge. Vänteläge inträffar och inget annat val är möjligt. när aktiv kyla är tillåtet samtidigt som behov av kom- pressordrift saknas. HPAC S40 | SE...
  • Seite 17 Här kan du tvångsstyra de olika komponenterna i anlägg- ningen. Dock är de viktigaste skyddsfunktionerna aktiva. OBS! Tvångsstyrning är endast avsett att användas i felsökningssyfte. Att använda funktionen på annat sätt kan medföra skador på ingående komponenter i ditt klimatsystem. HPAC S40 | SE...
  • Seite 18: Tekniska Uppgifter

    MÅTT TEKNISKA DATA HPAC S40 Spänning 230V ~50 Hz Höjd Bredd Djup Avsedd för värmepumpar 5–17 Röranslutning R25 (1”) Vikt Ämnen enligt förordning (EG) nr. 1907/2006, artikel 33 (Reach) Bly i mässingsdetaljer Art nr 067 624 HPAC S40 | SE...
  • Seite 19 HPAC S40 | SE...
  • Seite 20: English

    English HPAC S40 must be installed via an isolator Important information switch. The cable area has to be dimensioned based on the fuse rating used. SAFETY INFORMATION If the supply cable is damaged, only NIBE, This manual describes installation and service proced- its service representative or similar author- ures for implementation by specialists.
  • Seite 21 It must be disposed of at a special waste station or dealer who provides this type of service. Improper disposal of the product by the user results in administrative penalties in accordance with current le- gislation. HPAC S40 | GB...
  • Seite 22: General

    The heat pump has an integrated control system to control heating/cooling, integrated circulation pumps and is connected via the HPAC S40 module to the ex- ternal collector and the building’s climate system for heating and cooling.
  • Seite 23: Inspection Of The Installation

    HPAC S40 is installed on the wall. First screw the enclosed suspension bracket into place on the wall. Then hang HPAC S40 on the bracket. HPAC S40 can now be slid sideways to some extent, which facilitates the fitting of the pipes.
  • Seite 24: Pipe Connections

    (installed as close to the cooling module as possible), and particle filter (supplied with the heat pump) are to be fitted in such a way that HPAC S40 is also protected. Ensure to post-tighten all hydraulic connections If HPAC S40 is connected to a system with thermostats...
  • Seite 25 There are signs at the sides of the valves where it can be checked that the valve outlets point in the directions described above. Caution When changing the heating/cooling mode, there is a delay of approximately 60 seconds before the valves change their positions. HPAC S40 | GB...
  • Seite 26: Expansion Vessel

    Where the system may be operated at low temperat- ures, any convection fan used must be fitted with a drip tray and drain connection. PRESSURE DROP DIAGRAM HPAC S40 (25% propylene glycol, 5 °C) Tryckfall Pressure drop (kPa) (kPa) Flow (l/s) Flöde...
  • Seite 27: System Diagram

    OUTLINE DIAGRAM, HEAT PUMP WITH System diagram HPAC S40 AND 2-PIPE UKV In cases where the system volume in the climate sys- -EB100-BT25 -EQ1-GP10 tem is below20 l/kW (heat pump output at 7/45 °C) -EB100-BT71 and/or the flow in the climate system is choked uncon-...
  • Seite 28: Electrical Connection

    Accessory 2 Use a suitable tool to release/lock cables in terminal AA5-X4 blocks. POWER CONNECTION HPAC S40 is factory fitted with power cable and plug (W101, length 3 metres). CONNECTION OF SENSORS AND EXTERNAL BLOCKING Caution OVERVIEW ACCESSORY BOARD (AA5)
  • Seite 29 24 23 22 21 20 19 18 17 16 15 14 13 ANY (EQ1-GP10) An external circulation pump (GP10) for the climate AA5-X2 system can, if necessary, be connected to HPAC S40. Passive cooling Connect the circulation pump (GP10) to AA5-X9:8 (230 V), AA5-X9:7 (N) and X21:5 (PE).
  • Seite 30: Program Settings

    Program settings The DIP switch (S2) on the accessory board (AA5) must be set as follows. Program setting of HPAC S40 can be performed via the start guide or directly in the menu system in your com- patible heat pump.
  • Seite 31 Setting range: -5 – 40 °C Depending on which accessory is used the setting range can vary. MENU 4.2.3 - SG READY Affect cooling With low price mode of "SG Ready" and cooling opera- tion the indoor temperature is not affected. HPAC S40 | GB...
  • Seite 32 Passive cooling, auto: Here, you set whether the heating medium pump is to be regulated automatically or manually. Passive cooling, manual: If you have opted to control the heating medium pump manually, you set the desired pump speed here. HPAC S40 | GB...
  • Seite 33 If BT74 is installed, it will be preselected and no other option is possible. Set point value cool/heat sensor: Here, you can set the indoor temperature at which the installation will change between heating and cooling operation. HPAC S40 | GB...
  • Seite 34: Technical Data

    HPAC S40 Voltage 230V ~50 Hz Height Width Depth Intended for heat pumps 5–17 Pipe connections R25 (1”) Weight Substances according to Directive (EG) no. 1907/2006, article 33 (Reach) Lead in brass components Part No. 067 624 HPAC S40 | GB...
  • Seite 35: Deutsch

    Außenlufttem- ren sind. peratur Dieses Handbuch verbleibt beim Kunden. HPAC S40 muss über einen allpoligen Dieses Gerät darf von Kindern ab einem Schalter installiert werden. Der Kabelquer- Alter von 8 Jahren sowie von Personen schnitt muss der verwendeten Absicherung mit eingeschränkten physischen, sensori-...
  • Seite 36: Kennzeichnung

    über den normalen Hausmüll entsorgt werden. Stattdessen muss es bei speziellen Entsorgungseinrichtungen oder Händlern abgegeben werden, die diese Dienstleistung anbieten. Eine unsachgemäße Entsorgung des Produkts durch den Benutzer zieht Verwaltungsstrafen gemäß gelten- dem Recht nach sich. HPAC S40 | DE...
  • Seite 37: Allgemeines

    KONSTRUKTION DES KÜHLMODULS Allgemeines Das Zubehör HPAC S40 ist ein Klimamodul für Systeme mit kompatibler Wärmepumpe. Die Wärmepumpe ver- fügt über ein integriertes Regelgerät zur Regelung von Heizung bzw. Kühlung sowie eingebaute Umwälzpum- pen. Der Anschluss erfolgt über das HPAC S40-Modul an den externen Kollektor und das Klimatisierungssys- tem des Gebäudes für Heizung und Kühlung.
  • Seite 38: Transport Und Lagerung

    MONTAGE HPAC S40 wird an der Wand montiert. Bringen Sie zunächst die mitgelieferte Aufhängekonsole an der Wand an. Hängen Sie dann HPAC S40 an der Konsole auf. HPAC S40 lässt sich nun leicht seitlich verschieben, wodurch die Rohrinstallation vereinfacht AA5-F1 wird.
  • Seite 39: Rohranschluss

    Dieses wird in Form von Propylenglykol zugegeben (kein schriften ausgeführt werden. Die maximale Rücklauftem- Ethanol verwenden!). Die Mischung besteht aus etwa peratur für HPAC S40 beträgt etwa 50 °C, die maximale 25 % Propylenglykol. Die restlichen Prozent sind Was- Ausgangstemperatur von der Wärmepumpe liegt bei ser.
  • Seite 40 An den Ventilseiten befinden sich Schilder, mit deren Hilfe überprüft werden kann, ob die Ventilausgänge entsprechend den o.g. Angaben ausgerichtet sind. ACHTUNG! Bei einer Änderung des Heiz-/Kühlmodus wechseln die Ventile ihre Stellung mit einer Verzögerung von ca. 60 s. HPAC S40 | DE...
  • Seite 41: Druckausdehnungsgefäß

    Material isoliert werden. Wenn das System für den Einsatz bei niedrigen Tempe- raturen ausgelegt ist, muss ein eventuell vorhandener Gebläsekonvektor mit Tropfschale und Ablaufanschluss ausgestattet sein. DRUCKABFALLDIAGRAMM HPAC S40 (25 % Propylenglykol, 5 °C) Tryckfall Druckverlust (kPa) (kPa) Fluss (l/s) Flöde (l/s) A: Passive Kühlung...
  • Seite 42: Systemprinzip

    PRINZIPSKIZZE WÄRMEPUMPE MIT Systemprinzip HPAC S40 UND 2-ROHR-UKV Wenn das Systemvolumen im Klimatisierungssystem -EB100-BT25 -EQ1-GP10 unter 20 l/kW (Wärmepumpenleistung bei 7/45 °C) liegt -EB100-BT71 und bzw. oder der Durchfluss im Klimatisierungssystem -CP10 unkontrolliert gedrosselt wird, ist ein UKV-Tank zur Vo- lumen- und Durchflussvergrößerung zu installieren.
  • Seite 43: Elektrischer Anschluss

    • Um Störungen zu vermeiden, dürfen Fühlerkabel für KOMMUNIKATIONSLEITUNG externe Schaltkontakte nicht in der Nähe von Stark- stromleitungen verlegt werden. HPAC S40 umfasst eine Zubehörplatine (AA5), die direkt über die Basisplatine des Hauptprodukts (Anschlussklem- • Der minimale Kabelquerschnitt der Kommunikations- me AA2-X30) angeschlossen wird.
  • Seite 44: Anschluss Von Fühler Und Extern Geschalteter Blockierung

    UMWÄLZPUMPE (EQ1-GP10) Extern AA25 Eine externe Umwälzpumpe (GP10) für das Klimatisie- rungssystem kann bei Bedarf mit HPAC S40 verbunden werden. 24 23 22 21 20 19 18 17 16 15 14 13 Verbinden Sie die Umwälzpumpe (GP10) mit AA5-X9:8 AA5-X2 (230 V), AA5-X9:7 (N) und X21:5 (PE).
  • Seite 45: Programmeinstellungen

    Programmeinstellungen Wenn erhöhter Kühlbedarf besteht und alle Verdichter im Kühlbetrieb arbeiten und die Gradminuten für die Die Programmeinstellung von HPAC S40 kann per Kühlung ihre maximale Grenze erreicht haben, besteht Startassistent oder direkt im Menüsystem der kompati- die Möglichkeit, eine Zusatzkühlung hinzuzuschalten.
  • Seite 46: Menü 1.3 - Raumfühlereinstellungen

    Hier können Sie bei speziellem Bedarf Ihre eigene Brauchwasserbetrieb, ein. Welche Betriebsmodi geän- Kühlkurve definieren, indem Sie die gewünschten Vor- dert werden können, hängt davon ab, welches Zubehör lauftemperaturen bei unterschiedlichen Außenlufttem- angeschlossen ist. peraturen vorgeben. Vorlauftemp. Einstellbereich: -5 bis 40°C HPAC S40 | DE...
  • Seite 47: Menü 7.1.7 - Kühlung

    Aktive Kühlung, manuell: Wenn Sie die manuelle Rege- lung der Heizungsumwälzpumpe ausgewählt haben, stellen Sie hier die gewünschte Pumpendrehzahl ein. Passive Kühlung, Auto: Hier stellen Sie ein, ob die Hei- zungsumwälzpumpe automatisch oder manuell geregelt werden soll. HPAC S40 | DE...
  • Seite 48: Menü 7.1.10.2-Automoduseinstellungen

    Rückkehr zum Heizbetrieb erfolgt (oder um- gekehrt). Als Kühl-/Heizfühler verwenden Hier legen Sie fest, welcher Fühler für Kühlung/Heizung verwendet werden soll. Wenn BT74 installiert ist, ist dieser voreingestellt und es ist keine andere Einstellung möglich. HPAC S40 | DE...
  • Seite 49: Technische Daten

    TECHNISCHE DATEN HPAC S40 Spannung 230 V ~ 50 Hz Höhe Breite Tiefe Vorgesehen für Wärmepumpen 5–17 Rohranschluss R25 (1”) Gewicht Stoffe gemäß Verordnung (EG) Nr. 1907/2006, Artikel 33 (Reach) Blei in Messingbauteilen Art.nr. 067 624 HPAC S40 | DE...
  • Seite 50: Wiring Diagram

    WIRING DIAGRAM HPAC S40...
  • Seite 51: Kontaktinformation

    FINLAND FRANCE GERMANY NIBE Energy Systems Oy NIBE Energy Systems France SAS NIBE Systemtechnik GmbH Juurakkotie 3, 01510 Vantaa Zone industrielle RD 28 Am Reiherpfahl 3, 29223 Celle Tel: +358 (0)9 274 6970 Rue du Pou du Ciel, 01600 Reyrieux Tel: +49 (0)5141 75 46 -0 info@nibe.fi...
  • Seite 52 WS release date: 2021-03-18 17:35 Publish date: 2021-03-29 16:56 This manual is a publication from NIBE Energy Systems. All product illustrations, facts and specifications are based on current information at the time of the publication’s approval. NIBE Energy Systems makes reservations for any factual or printing errors in this manual.