TECHNICAL DESCRIPTION

This product, supplying breathing air to the user, has been tested in accordance with
EN 1146, ISO 23269-1 & 42 CFR (NIOSH), and is to be used according local regulations.
Manufacturer:
Interspiro AB
Box 2853, 18728 Täby, Sweden.
Spiroscape provides a constant flow of breathable air for 15 minutes.
When the air ceases to flow, a valve opens automatically and the user can breathe the
surrounding air without taking off the hood.This ensures that a user is not asphyxiated
if they lose consciousness when the air supply runs out.By shutting off the air flow
manually, a user can wear the hood during an exercise or in standby situations.
The air in the cylinder must meet the requirements of EN 12021, be free from oil and
toxic substances and have a low humidity.
2.1
Approved only when the compressed air cylinder is fully charged with air that meets
the requirements of the Compressed Gas Association Specifications G-7-1 for Type 1,
Grade D Air or higher quality, as well as having a dew point of –65 °F (–54 °C) or drier
(24 ppm v/v or less) and a particle level below 5 mg/m3 of air.
2.2
Interspiro's auto-fill adapter, see [figure 1], provides a quick and simple means
of charging the cylinder. No tools are required. The adapter prevents the 200 bar
cylinder from being charged to 300 bar.
Instructions for using the auto-fill adapter are given in chapter 5.
3

DONNING AND USE

Collect the Spiroscape from its storage location.
1.
Place the neck strap over your head as shown in [figure 2].
2.
With your right hand, distinctly pull the loop strap connected to the quick-start
3.
ring [ref d, figure 5] upwards; see [figure 2]. This is what happens when you pull
the strap:
The anti-tamper seal [ref a, figure 5] is broken.
l
The quick-start ring [ref c, figure 5] is pulled away from the cylinder valve and the
l
air starts to flow.
The zipper opens (make sure that the zipper opens all the way).
l
NOTE: THE DURATION TIME OF THE APPARATUS STARTS NOW.
8
LIMITATIONS ACCORDING TO NIOSH (ONLY APPLICABLE TO THE USA)