Installation example - multi-cylinder system to operate large cylinders
NOTE
If re-assembling, change the gaskets.
Make sure that the gaskets sit properly in the mounting and that the screws are
tightened.
NOTE
For outdoor applications the product must be located or protected so that no dripping
water can enter.
We recommend installation in a cabinet or protective box.
NOTE
We recommend that you install the pressure regulator at an angle to the breather.
This allows condensation to flow away better.
NOTE
Observe the evaporation capacity of gas cylinders.
Temperature change of the gas.
The cylinder pressure falls below the required inlet pressure of the operating
regulator.
Proper operation of the LPG system is no longer guaranteed.
NOTE
Install the pressure regulator so that it is not under tension.
Use the regulator support.
Part No. 05 004 52 a
Low pressure regulator Type FL 90-4, Type FL 91-4
7 / 12