ding LED is flashing, then press the SET button: the LAMP/CORT. LED lights up and
remains constant. Repeat the operation to restore the default configuration.
To enable the courtesy light, repeat the operation above, by pressing the SEL button twice
(LAMP/CORT LED flashes rapidly) instead of once. Repeat the operation to restore the
default configuration.
Flashing beacon function while the unit is paused: The 230 V a/c output will activate
every time automation takes place, for the duration of the motor timer. If the Pause Time
is stored, the 230 V a/c output will also be active during the Pause.
Flashing Beacon Operation: The 230 V a/c output will activate every time automation
takes place, for the duration of the motor timer.
Courtesy Light Operation: The 230 V a/c output will activate for 3 minutes every time an
opening command is given.
4) T. MOT: (Motor operation time of max. 4 minutes)
The control unit is supplied by the manufacturer with the Automatic Motor Timer enabled,
this way the control unit removes the power supply from the motor 1 second after it has
reached the motor's internal stop limit. If there is an established motor operation time and
an Automatic Motor Timer which is disabled, proceed as follows when the shutter is
closed to perform the programming process: use the SEL button to reach the stage where
the T. MOT LED flashes, then press press the SET button briefly; the Motor will begin the
Opening cycle. When the shutter reaches the desired position press the SET button. The
motor time is stored and the T. MOT. LED remains lit in a constant manner.
To restore the initial configuration (with the Automatic Motor Timer function enabled) nav-
igate to the stage where the T. MOT. LED is flashing then press the SET button twice with-
in 2 seconds; the LED switches off and the operation is complete.
During programming the radio control button on the control unit can be used instead of the
SET button, if stored previously.
5) T. PAUSA: (Programming aut. closing time of max. 4 min.)
The control unit is supplied by the manufacturer without an automatic closing procedure.
To enable the automatic closing function proceed as follows: use the SEL button to reach
the stage where the T. PAUSA LED is flashing, then press the SET button, wait for the
desired pause time, then press the SET button again for a moment; the automatic closing
time is stored and the T. PAUSA LED remains lit in a constant manner.
To restore the initial configuration (without automatic closing) navigate to T.PAUSA when
the corresponding LED is flashing then press the SET button twice within 2 seconds; the
LED switches off and the operation is complete.
During programming the radio control button on the control unit can be used instead of the
SET button, if stored previously.
6) SEL DS1: (Selection of Safety Device 1)
The control unit is supplied by the manufacturer with the DS1 safety device operating as
follows: action is not taken into account during the opening stage but causes inverted
motor action during the closing stage. If you wish to make it possible to intervene in the
opening or closing process, causing the motor to stop immediately, proceed as follows:
use the SEL button to reach the stage where the SEL DS1 LED is flashing and press the
SET button: the SEL DS1 LED lights up in a constant manner and programming is com-
pleted. Repeat the operation to restore the previous configuration.
7) SEL DS2: (Selection of Safety Device 2)
The control unit is supplied by the manufacturer with the DS2 safety device operating as
follows: action is not taken into account during the opening stage but causes inverted
motor action during the closing stage. If you wish to make it possible to intervene in the
opening or closing process, causing the motor to stop immediately and a brief inversion
in the motor direction, proceed as follows: use the SEL button to reach a stage where the
SEL DS2 LED is flashing and press the SET button: the SEL DS2 LED lights up in a con-
stant manner and programming is completed. Repeat the operation to restore the previ-
ous configuration.
8) SEL DS3: (Selection of Safety Device 3)
The control unit is supplied by the manufacturer with the DS3 safety device operating as
follows: action is not taken into account during the opening stage but causes inverted
motor action during the closing stage. If you wish to make it possible to intervene in the
opening or closing process, causing the motor to stop immediately, proceed as follows:
use the SEL button to reach a stage where the SEL DS3 LED is flashing and press the SET
button: the SEL DS3 LED lights up in a constant manner and programming is completed.
Repeat the operation to restore the previous configuration.

EXTENDED MENU

The control unit is supplied by the manufacturer with the possibility of selecting only the
functions listed in the main menu.
To enable the functions of the extended menu proceed as follows: press and hold the SET
button for 5 seconds; the DS2 and DS3 LEDs will start flashing alternately. the user then
has 30 seconds in which to select the functions of the extended menu using the SEL and
SET buttons, after 30 seconds the control unit returns to the main menu.
EXTENDED MENU
Reference LED
LED Off
A) CODE
remote PGM = OFF
B) INB.CMD.AP.
est DS1 = OFF
C) LAMP/CORT
Test DS2 = OFF
D) T. MOT.
Test DS3 = OFF
E) T. PAUSA
DS2 intervention = Close
F) SEL DS1
DS3 intervention = Close
G) SEL DS2
H) SEL DS3
A) CODE (Remote programming of radio control):
The control unit allows the transmission code to be programmed by remote, without using
the SEL button.
To programme the transmission code remotely proceed as follows: send the radio control
code continuously for more than 10 seconds; the control unit will enter the programming
mode as described above for the CODE LED in the main menu.
The control unit is supplied by the manufacturer with remote programming of the trans-
mission code not enabled; to enable the function proceed as follows: check that the
- 9 -
LED On
remote PGM = ON
Test DS1 = ON
Test DS2 = ON
Test DS3 = ON
DS2 intervention = Open
DS3 intervention = Open
Flashing beacon ON/OFF
Flashing beacon ON/OFF