ELECTRONIC CONTROL UNIT LRX 2197
Single-phase electronic control unit for the automation of rolling shutters with incorporat-
ed radio receiver.
- Mod. LG 2197
- Mod. ( LR
2197 )
- Mod. ( LR 2197 / 330 )
- Mod. ( LR 2197 / 418 )
- Mod. LRS 2197
- Mod. LRS 2197 SET
- Mod. LRH 2197
( ) Product intended for those countries where its use is permitted

TECHNICAL DATA:

- Power supply
- Flashing beacon output
- Motor output
- Photoelectric cells power supply
- Low voltage safety features and commands
- Operating temperature
- Radio receiver
- Op. transmitters
- Max stored TX codes
- Box dimensions
- Container
TERMINAL BOARD CONNECTIONS:
CN1:
1 : 230 V a/c line input (Phase).
2 : 230 V a/c line input (Neutral).
3 : Clean contact output for Flashing Beacon/Courtesy Light.
4 : Clean contact output for Flashing Beacon/Courtesy Light.
5 : Opening motor output.
6 : Shared motor output.
7 : Closing motor output.
CN2:
1 : Photoelectric cell control and power supply (24 V a/c).
2 : Photoelectric cell control and power supply (GND).
3 : PUL open-close command button input (NA).
4 : Shared GND input.
5 : DS1 safety device input.
6 : DS2 safety device input.
7 : Shared GND input.
8 : DS3 safety device input.
9 : Earth antenna input.
10 : Antenna hot pole input.
: Without radio receiver
: 306
Mhz
: 330
Mhz
: 418
Mhz
: 433.92
Mhz
: 433.92 Mhz narrow band
: 868.3 Mhz narrow band
: 230 V a/c 50-60 Hz 1100 W max.
: 230 V a/c 500 W max.
: 230 V a/c 500 W max.
: 24 V a/c 3 W max.
: 24 V c/c
: -10 ÷ 70 °C
: see model
: 12-18 Bit or Rolling Code
: 75
: 110 x 121 x 47 mm.
: ABS V-0 (IP54).
OPERATIONAL DATA:
Operation with push-button station:
The following operation is obtained using the low voltage push-button station (PUL) to
control the shutter:
the first press opens the shutter until the end of the motor timer and the second press clos-
es it; if pressed again before the end of the motor time, the control unit stops movement
whether the shutter is opening or closing.
A further command restarts motion in the opposite direction.
Operation using different models of Radio Control:
Different models of radio control may be programmed: by storing a code (1 button) a cyclic
step by step operation (Open - Stop - Close) may be achieved, and by storing two differ-
ent codes (2 buttons) separate commands are created, one for opening and one for clos-
ing. Storing three different codes (3 "BeFree" series buttons) produces three distinct com-
mands: the first for Open, the second for Stop and the third for Close.
Operation using a 1-button radio control:
The following type of operation is obtained using a radio control with a single button: the
first press controls the opening movement of the shutter until the motor timer stops. The
second press controls the closing movement of the shutter. If the button is pressed before
the motor stops running, the control unit will stop the shutter moving and the button will
need to be pressed again to reactivate the motor in the opposite direction.
Operation using a 2-button radio control:
The following type of operation is obtained using a radio control with 2 buttons: the first
button ("Up", corresponding to the opening movement) controls opening until the motor
stops running and the second button ("Down", corresponding to the closing movement)
controls the Closure of the shutter. If the opening movement is interrupted with another
"Up" command, the motor will continue to run in the upward movement direction. If, how-
ever, the movement is interrupted with a "Down" command, the control unit will stop the
motor. The procedure is the same for the closing movement phase.
Operation using a 3-button radio control (BeFree series):
The following type of operation is obtained using a radio control from the BeFree series:
the Up button controls the opening movement until the set motor time has elapsed, the
Stop button makes the shutter stop and the Down button controls the closure of the shut-
ter. If a stop command is sent during the opening or closing movement, the control unit
causes this movement to stop. If a command which is the opposite direction to the cur-
rent movement is sent during the opening or closing movement, the control unit causes
the shutter to change direction.
Automatic closing:
The control unit can close the shutter automatically without sending additional commands.
The selection of this operation mode is described in the Pause Time programming mode.
DS1 safety device:
The DS1 input anticipates the connection of a general safety device with contact (NC). If
not used, this input must be bridged.
Action is not taken into account during the opening stage but causes inverted motor action
during the closing stage. Another safety device operating mode is described in the SEL
DS1 Programming section.