Herunterladen Inhalt Inhalt Diese Seite drucken

Seav LRX 2197 Bedienungsanleitung Seite 8

Elektronische schalttafel
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
DS2 safety device:
The DS2 input anticipates the connection of a general safety device with contact (NC). If
not used, this input must be bridged.
Action is not taken into account during the opening stage but causes inverted motor action
during the closing stage. Another safety device operating mode is described in the SEL
DS2 Programming section.
DS3 safety device:
The DS3 input anticipates the connection of a general safety device with contact (NC). If
not used, this input must be bridged.
Action is not taken into account during the opening stage but causes inverted motor action
during the closing stage. Another safety device operating mode is described in the SEL
DS3 Programming section.
Operation with TIMER:
The control unit may be connected to a timer instead of using the open-close command
button (PUL).
Example: at 8:00 a.m. the timer closes the contact and the control unit opens the shutter;
at 6:00 p.m. the timer opens the contact and the control unit closes the shutter. Between
8:00 a.m. and 6:00 p.m. at the end of the opening phase, the control unit disables the
flashing beacon, the automatic closing stage and the radio controls.
PROGRAMMING:
SEL button: selects the type of function to be stored; selection is indicated by a flashing
LED.
The desired function can be selected by pressing the button repeatedly. The selection
remains active for 10 seconds (indicated by the flashing LED); after 10 seconds, the con-
trol unit returns to its original status.
SET button: programmes the information according to the type of function selected pre-
viously using the SEL button.
IMPORTANT: The function of the SET button can be replaced with the radio control, if pro-
grammed previously (CODE LED on).
MAIN MENU
The control unit is supplied by the manufacturer with the possibility of selecting some
important functions.
MAIN MENU
Reference LED
LED Off
1) CODE
No code
2) INB.CMD.AP
Disabled
3) LAMP/CORT
Flashing
4) T. MOT.
Automatic motor time
5) T. PAUSA.
Without aut. closing
6) SEL DS1
CH = INV.
7) SEL DS2
CH = INV.
8) SEL DS3
CH = INV.
LED On
Code entered
Enabled
Courtesy light
Time programmed
With aut. closing
AP/CH = BL
AP/CH = BL+INV.
AP/CH = BL
- 8 -
1) CODE: (Radio control code)
The control unit can store up to 75 radio controls with different fixed or rolling codes.
Programming using a 1- or 2-button radio control:
To programme the transmission codes in the radio control, proceed as follows: press the
SEL button and the CODE LED will begin to flash; at the same time send the first code
("Up", corresponding to the opening movement) on the radio control. At this point the
CODE LED will begin to flash quickly. Send the second code ("Down", corresponding to
the closing movement) to be stored and the CODE LED will remain lit: programming is now
complete. If the second code is not sent within 10 seconds the control unit exits the pro-
gramming stage, selecting the function using a single button on the radio control.
Programming using a 3 button radio control in the "BeFree Series":
The control unit allows you to store the whole "BeFree" radio-control by programming only
the UP button. To programme the "BeFree" radio-control codes, follow this procedure:
press the SEL button; the CODE LED begins to flash. Press the UP button of the desired
radio control at the same time; the CODE LED will remain lit and programming will be com-
plete.
Deleting the codes: To delete all transmission codes stored in the memory, proceed as
follows: press the SEL button; the CODE LED starts flashing. Then press the SET button;
the CODE LED switches off and the procedure is complete.
Maximum number of radio controls which can be stored: The control unit can store up
to 75 radio controls with different fixed or rolling codes. If the maximum number of radio
controls has been reached, and a programming process started, the control unit will indi-
cate that the programming process has failed by flashing all the LEDs except the CODE
LED, which will remain lit in a constant manner. After 10 seconds the control unit exits the
programming mode.
2) INB. CMD. AP: (command inhibition during opening and pause time, if entered)
The command inhibition function during opening and pause time, if entered, is used when
automation includes the loop detector. During opening or pause time the control unit
ignores the commands given by the loop detector, push-button station and radio control.
During the closing phase a command sent by the loop detector, push-button station or 1-
button radio control will cause the motor direction to be inverted; if operating with a 2-but-
ton radio control the button corresponding to opening will cause the motor direction to
invert and the closing button is ignored; if operating with a radio control in the BeFree
series the opening button causes inversion, the closing button is ignored and the Stop but-
ton causes the motor to stop.
The control unit is supplied with the default setting of the command inhibition function dur-
ing opening and pause time not enabled. To enable the function proceed as follows: use
the SEL button to navigate to INB.CMD.AP when the relevant LED is flashing, then press
the SET button: the INB.CMD.AP LED lights up and remains constant. Repeat the opera-
tion to restore the previous configuration.
3) LAMP/CORT: (Selection of flashing beacon or courtesy light)
The control unit has an output of 230 V a/c 500 W for connection to a flashing beacon or
courtesy light. The control unit is supplied by the manufacturer with the flashing beacon
function enabled (even when the unit is paused). To enable the flashing beacon function
proceed as follows: use the SEL button to navigate to LAMP/CORT. when the correspon-

Werbung

Inhaltsverzeichnis
loading