We advise that you also take note of the following recommendations:
Before shutter automation, it is necessary to check the product is in good condition and
that it complies with EN 12604 and the Machines Directive.
The wiring of external electrical components must comply with EN 60204-1 as amend-
ed in section 5.2.7 of EN 12453. Power supply leads and connection cables must be
secured through the use of cable clamps, which are supplied with the product.
The motor reducer used to move the shutter must comply with section 5.2.7. of EN
12453.
If present, the push-button station for manual control must be mounted in such a way
that the user is not placed in a dangerous situation, in compliance with point 5.2.8 of
EN 12453.
The control unit is not equipped with a 230 V a/c electric line sectioning device. The
installer is responsible for installing a sectioning device in the system. An omnipolar
switch with overheating category III must be installed. The sectioning device must be
positioned so that it is protected against accidental closure, in compliance with section
5.2.9 of standard EN 12453.
In compliance with EN 12453 it is recommended that motor reducers fitted with an
electromechanical unlocking device are used, so that the door can be moved manual-
ly if necessary.
In compliance with point 5.4.3 of EN 12453 electromechanical unlocking systems or
similar devices should be used as these allow the door to stop safely at its stop limit.
Power supply and motor connection cables which are suitale for use in conjunction with
the pg9 cable clamps provided must have an external diameter which measures
between 4.5 and 7 mm. The internal conductor wires must have a nominal cross-sec-
tion of 0.75 mm
2
. If a channel is not used, we recommend that cables in H05RR-F mate-
rial are used.
The D.S. Power Supply output must be dedicated to the powering of photoelectric
cells. It must not be used for other purposes.
The safety devices connected to DS1 must be powered using the D.S. Power Supply
output. If several of the devices mentioned above are used, they must be connected in
series.
For the radio receiver to operate correctly when two or more control units are used, we
recommend that you install the devices at least 3 metres away from each other.
Warning
All operations which require the casing to be opened (such as wire connection, pro-
gramming, etc.) must be carried out during installation, by skilled staff only. For any
other procedure which requires the casing to be opened again (re-programming,
repairs or site modifications), please contact the technical assistance service.
The below products: Electronic Control Unit:
LG 2197 - LRS 2197 - LRS 2197 SET - LRH 2197
conform to the specifications in the Directives
RED 2014/53/EU, EMC 2014/30/EU,, LVD 2014/35/EU.
F
U
- I
OR THE
SER
MPORTANT
- The device should not be used by children or by individuals with reduced physical or
psychological abilities unless supervision is provided or instruction given on how to
operate it.
- Do not let children play with the device; keep radio controls out of their reach.
- CAUTION: Keep this instruction manual in a safe place and adhere to the important
safety instructions contained within it. Non-adherence to these instructions may lead to
property damage and serious accidents.
- Examine the system frequently to check for any signs of damage. Do not use the
device if it needs to be repaired.
- 12 -