Herunterladen Inhalt Inhalt Diese Seite drucken

User Instructions - 3M Speedglas 9100 FX Serie Bedienungsanleitung

Welding shield
Vorschau ausblenden Andere Handbücher für Speedglas 9100 FX Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6
Instruction 3M™ Speedglas™ 9100 FX Series Welding Shields 1ï/

USER INSTRUCTIONS

Please read these instructions in conjunction with other
relevant user instructions for 3M Speedglas welding filters,
3M air delivery units and reference leaflets where you will
find information on approved combinations of air delivery
units, spare parts and accessories.
SYSTEM DESCRIPTION
The 3M Speedglas 9100FX help protect the wearer's eyes
and face from sparks/spatter, harmful ultra-violet radiation
(UV) and infra-red radiation (IR) resulting from certain arc/
gas welding processes. The product is designed to be used
only with 3M Speedglas 9100 welding filters and protection
plates. The 3M Speedglas 9100FX air also protects against
certain airborne contaminants when used with an approved
air delivery unit.
WARNING
Proper selection, training, use and maintenance are
essential in order for the product to help protect the
wearer. Failure to follow all instructions on the use of
these protection products and/or failure to properly wear
the complete product during all periods of exposure may
adversely affect the wearer's health, lead to severe or life
threatening illness, injury or permanent disability.
For suitability and proper use follow local regulations, refer
to all information supplied.
Particular attention should be given to warning
statements
where indicated.
APPROVALS
These products meet the requirements of the European
Community Directive 89/686/EEC (Personal Protective
Equipment Directive) and are thus CE marked. The
products comply with the harmonized European Standards
EN 175 and EN 166. Certification under Article 10, EC
Type-Examination has been issued by DIN Certco Prüf-
und Zertifierungszentrum (Notified body number 0196).
Speedglas 9100 FX Air respiratory systems complies with
the harmonized standards EN 12941 and EN 14594. 3M
Speedglas 9100 FX Air systems incorporating powered
air filter units or supplied air regulators units marked
CE0194 have had certification under Article 10, EC-Type
Examination and Article 11, EC Quality Control issued by
INSPEC International Ltd.
3M Speedglas 9100 FX Air systems incorporating powered
air filter units or supplied air regulators units marked
CE0086 have had certification under Article 10, EC-Type
Examination and Article 11, EC Quality Control issued by
BSI.
LIMITATIONS OF USE
Only use with original 3M Speedglas brand spare
parts and accessories listed in the reference leaflet
and within the usage conditions given in the Technical
Specifications.
The use of substitute components, decals, paint or other
modifications not specified in these user instructions might
seriously impair protection and may invalidate claims under
the warranty or cause the product to be noncompliant with
protection classifications and approvals.
Eye
protectors
worn
over
spectacles may transmit impacts thus creating a hazard
to the wearer.
The Speedglas welding shield is not designed for
overhead welding/cutting operations when there is a risk
of burns from falling molten metal.
3M™SPEEDGLAS™FX AIR
EQUIPMENT MARKING
3M 1 BT N (1= optical class, BT=medium energy impact at
extremes of temperatures (-5°C and +55°C), N=Resistance
to fogging)
3M EN166BT (medium energy impact at extremes of
temperatures (-5°C and +55°C) BT)
3M EN175B (medium energy impact B)
3M EN12941 TH3 (assigned protection factor 40, nominal
protection factor 500, higher strength requirement for
breathing hose and couplings)
3M EN12941 TH2 (assigned protection factor 20, nominal
protection factor 50, medium strength requirement for
breathing hose and couplings)
3M EN14594 2B/3B (assigned protection factor 20/40,
nominal protection factor 50/200, higher strength
requirement)
Additional markings on the product refer to other standards.
PREPARATION FOR USE
Carefully check that the product is complete (see fig A:1),
undamaged and correctly assembled, any damaged or
defective parts must be replaced before each use.
standard
ophthalmic
OPERATING INSTRUCTIONS
Adjust the welding shield according to your individual
requirements to reach the highest comfort and protection.
The SideWindows should be covered with the cover
plates in situations when other welders are working
beside you and in situations where reflected light can
pass through the SideWindows (see fig I:1)
Materials which may come into contact with the wearer's
skin are not known to cause allergic reactions to the
majority of individuals. These products do not contain
components made from natural rubber latex.
Do not use for respiratory protection against unknown
atmospheric contaminants or when concentrations of
contaminants are unknown or immediately dangerous to
life or health (IDLH).
Do not use in atmospheres containing less than 19.5%
oxygen (3M definition. Individual countries may apply their
own limits on oxygen deficiency. Seek advice if in doubt).
Do not use these products in oxygen or oxygen-enriched
atmospheres.
Leave the contaminated area immediately if: Any part
of the system becomes damaged, airflow into the
headtop decreases or stops, breathing becomes difficult,
dizziness or other distress occurs, you smell or taste
contaminants or irritation occurs.
High winds above 2m/s, or very high work rates (where
the pressure within the headtop can become negative)
can reduce protection. Adjust equipment as appropriate
or consider an alternative form of respiratory protective
device.
Users should be clean-shaven where the respirator's
face seal comes into contact with the face.
When working in cold environments the 52 30 01 antifog
visor plate shall be used due to risk of fogging.
= Read the instructions before use
The welding shield is heat resistant but can catch fire or
melt in contact with open flames or very hot surfaces.
Keep the shield clean to minimize this risk.
1

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Speedglas 9100 fxSpeedglas 9100 fx air9100 fx9100 fx-air

Inhaltsverzeichnis