• Insert the filter (30) in the water inlet fitting (29). Fit the seal (31) in the water inlet quick-fit
coupling (32) and screw up to the fitting (29). Operation B in Fig. 1.
• Fit the master switch (1) knob in its housing (7), ensuring that the notch R is lined up with
letter "0". Operation A in Fig. 1.
INSTALLATION - FLOOR OPERATION
WARNING
• Given the weight of the machine, the following operation must be performed by two
people.
• Carry the machine to the working position, taking care to place it stably on a flat surface.
Use the rubber feet (27) to position correctly.
INSTALLATION - WALL FIXING
• Identify an appropriate wall to fix the machine to: the machine must only be fixed to brick
or reinforced concrete walls not less than 10 cm/4 in thick; do not fix the machine to
plasterboard, wood, steel sheet walls or made from any other materials which
cannot support the plugs supplied.
• For wall fixing use only the plugs provided; if a plug is lost or damaged during installation,
contact a Specialized Technician for a replacement.
• Referring to the measurements given in Fig. 2, make four marks used as a reference for the
subsequent drilling operations: for the best position for use, it is advisable to drill the
three upper holes at a height of 150-160 cm/59-63 in from the ground.
• Using a 12 mm/0.47 in diameter bit (not supplied) suitable for drilling brick/reinforced concrete
walls, drill four holes approx. 70-80 mm/2.8-3.2 in deep (see also Fig. 3), on the marks made
previously. When drilling pay attention to the safety precautions given in the use
and maintenance manual supplied with the drill used. Also remember to check that
there are no pipe and/or electrical wiring channels underneath the drilling area.
• Place the plugs (9) in the holes, so that their necks are flush to the wall; do not push the
plugs into the hole or keep them sticking out from it.
• Using a 13 mm/0.5 in spanner (not supplied), screw in the screws (11) leaving a gap of approx.
10 mm/0.4 in between the washer (10) and the wall (see also Fig. 3).
WARNING
• Given the weight of the machine, the following operation must be performed by two
people.
20