AUTO
Auto range
The battery is not sufficient for proper operation
CAUTION!
Note on using the supplied safety test leads according the IEC /
EN 61010-031:2008:
Measurements in the field of overvoltage category CAT I or CAT II
can be performed with test leads without sleeves with a maximum of
up to 18mm long, touchable metallic probe, whereas for
measurements in the field of overvoltage category CAT III or CAT IV
test leads with put on sleeves, printed with CAT III and CAT IV must
be used, and therefore the touchable and conductive part of the
probes have only max. 4mm of length.
2.

Technical Data

Display
max. Voltage between
terminals and earth ground
Ranging Method
Sampling rate
Polarity indication
Overload indication
3 ½-digit 11 mm LCD display with
function annunciators, max.
indication: 1999
600 V DC/ACrms
Auto or manual
2,5 times per second
"-" displayed automatically
"OL" displayed