DESCRIPTION OF APPLIANCES
Electric cooking hob
Sturdy stainless steel structure standing on four height-adjustable legs. The outer covering is made
of stainless steel.
Each electric hotplate on the hob has a switch that allows the heat output to be varied from
minimum to maximum in seven positions. Safety is ensured by means of a temperature limiter
inside the hotplate.
The electric hotplates are made of cast iron with their heating element fixed beneath it, embedded in
a layer of insulating material.
Glass ceramic electric cooking hob
Sturdy stainless steel structure standing on four height-adjustable legs. The outer covering is made
of stainless steel.
The glass ceramic plate has a thickness suitable to transmit the heat and on its surface you will find
designed areas for cooking. Heat intensity is controlled by an energy regulator that varies the
working times of the special infrared heating elements beneath the glass ceramic. The appliance is
provided with a manually reactivating safety thermostat against overheating.
1/1 GN static electric oven
The cooking chamber is made of stainless steel. The bottom is entirely made of thick stainless steel
and it is strengthened by a series of ridges.
The removable grill is made of reinforced steel covered with a protective film. The insulation of the
cooking chamber and of the door is ensured by a layer of high temperature resistant ceramic fibre.
The oven has a thermostat, which allows the temperature to be regulated in a range between 90° C
and 300° C. Safety is ensured by a manually reactivating thermostat.
The chamber is heated by means of covered elements under the floor and on the ceiling.
PROVISIONS FOR INSTALLATION
Place (fig. 6 – p. 4)
It is advisable to install the appliance in a well ventilated room or under an extractor hood. The
appliance may be installed as a single unit or together with others. In both cases, if it is installed
near a wall of inflammable material, a minimum distance of 50 mm from the side and back walls
must be observed. In the event that it is not possible to observe this distance, protective measures
must be taken (e.g. use of sheets of refractory material) which ensure that the temperature of the
walls is within the established safety limits.
Installation
Installation operations, conversion to a voltage other than that envisaged, system or appliance start
up, ventilation work and any maintenance must be done by qualified personnel following the
manufacturer's instructions, observing current regulations and in compliance with the following
provisions (GB):
 Health and Safety at Work Act, 1974
 Codes of Practice, BS6173, 1982
 The Building Regulations, 1985
Pag. 28/45