4. TECHNICAL DATA
4.1 Electrical data
Supply voltage:
Absorbed power:
Maximum current:
Degree of protection:
Protection class:
4.2 Operating conditions
Flow rate:
Head:
Maximum working pressure:
Motor construction:
Noise:
MODEL
BPH-E 60/250.40
BPH-E 60/280.50
BPH-E 60/340.65
BPH-E 120/250.40
BPH-E 120/280.50
BPH-E 120/340.65
BPH-E 120/360.80
BPH-E 150/340.65
BPH-E 180/280.50
DPH-E 60/250.40
DPH-E 60/280.50
DPH-E 60/340.65
DPH-E 120/250.40
DPH-E 120/280.50
DPH-E 120/340.65
DPH-E 120/360.80
DPH-E 150/340.65
DPH-E 180/280.50
4.3 Temperature
Environment temperature:
Storage temperature :
Liquid temperature:
up to 110°C according to EN 60335-2-51
T. Max 120°C
4.4 EMC – electromagnetic compatibility–
BPH-E, DPH-E circulators respect standard EN
61800-3,
in
category
compatibility.
-
Electromagnetic
environment (in some cases measures to
reduce them may be requested).
-
Emissions of ducts – industrial environment
(in some cases measures to reduce them may
be requested).
The models with power lower than 1 kW need a 2.4
mH external filter at input, as requested by standard
EN 61000-3-2.
1x230 V 50-60Hz
See electrical data plate
See electrical data plate
IP44
H
from 13.8 to 59.76 m³/ h
see table
10 bar
CEI 2-3 – CEI 61-69
( EN 60335-2-41 )
directive EC 89/392/EEC
Head
H max (m)
7,3
7,4
6,9
11
11
10,1
10,9
13,7
17,5
7,3
8,1
7,2
11
11,8
10,4
11,1
14
18,2
0 ÷ 40°C
-10 ÷ 40°C
C2,
for
electromagnetic
emissions
–
industrial
ENGLISH
5. MANAGEMENT
5.1 Storage
All the circulators must be stored in a dry covered place,
with possible constant air humidity, free from vibrations
and dust.
They are supplied in their original pack in which they
must remain until the time of installation.
Otherwise the suction and delivery opening must be
accurately closed.
5.2 Transport
Avoid subjecting the products to needless impacts and
collisions. To lift and transport the circulator use lifting
devices with the aid of the pallet supplied with it
contemplated ).
5.3 Weight
The adhesive plate on the package shows the total
weight of the circulator.
6 INSTALLATION
6.1 Circulator installation
The circulator may be installed in heating systems
either on the delivery pipe or on the return pipe; the
arrow on the pump body indicates the direction of
flow.
Install the circulator as much as possible above the
minimum boiler level, and as far as possible from
curves, elbows and derivations.
To facilitate control and maintenance operations,
install a stop valve both on the suction pipe and on
the delivery pipe.
Before installing the circulator, flush the system
accurately with only water at 80°C. Then drain the
system
completely
substance that may have got into circulation.
Always fit the circulator with the
motor shaft in a horizontal position,
(fig.1)
Always fit the Dialogue in a vertical
position (fig.1)
Fig. 1
36
to
eliminate
any
(if
harmful